On the PCD1.M2, PCD3 and PCD2.M5 CPU's it's possible to change the TCP port number of the S-Web server by the use of the PG5 2.0 Device Configurator.
Communication interfaces for specific protocols for PCD3.M1xxx/..M2xxx M-Bus master interface module for up to 240 M-Bus slave addresses freely distributable on 2 M-Bus interfaces) - to be placed in I/O slots 0..3
Communication interfaces for specific protocols for PCD3.M1xxx/..M2xxx M-Bus master interface module for up to 60 M-Bus slave addresses freely distributable on 2 M-Bus interfaces - to be placed in I/O slots 0..3
Communication interfaces for specific protocols for PCD3.M1xxx/..M2xxx M-Bus master interface module for up to 20 M-Bus slave addresses freely distributable on 2 M-Bus interfaces - to be placed in I/O slots 0..3
In April 2022: the COSinus FW 1.28.51 was introduced into production for the systems: - PCD1.M0xx0/M2xx0, PCD2.M4x60, PCD3.Mxx60 and PCD3.M6880. In February 2019: the COSinus FW 1.28.37 was released as maintenance version for the systems: - PCD1.M0xx0/M2xx0, PCD2.M4x60, PCD3.Mxx60, PCD3.M6880 and PCD3.T665/T666/T668 . In June 2017: the COSinus FW 1.28.16 was introduced into production for the systems: - PCD1.M0xx0/M2xx0, PCD2.M4x60, PCD3.Mxx60, PCD3.M6880 and PCD3.T665/T666/T668 . the BACnet and LonIP FW 1.28.16 was put into production, which do support the BACnet Revision 14
In January 2024: the COSinus BACnet FW 1.28.59 was put on the support homepage. In April 2022: the COSinus FW 1.28.51 was introduced into production for the systems: - PCD1.M0xx0/M2xx0, PCD2.M4x60, PCD3.Mxx60 and PCD3.M6880. In February 2019: the COSinus FW 1.28.37 was released as maintenance version for the systems: - PCD1.M0xx0/M2xx0, PCD2.M4x60, PCD3.Mxx60, PCD3.M6880 and PCD3.T665/T666/T668 . In June 2017: the COSinus FW 1.28.16 was introduced into production for the systems: - PCD1.M0xx0/M2xx0, PCD2.M4x60, PCD3.Mxx60, PCD3.M6880 and PCD3.T665/T666/T668 . the BACnet and LonIP FW
When reading values from some specific M-Bus devices with the M-Bus modules PCD2/3.F27xx, the M-Bus driver may show the error "Missing value" even though all values are correctly returned by the device.
to use a PLC with SD Flash for example PCD3.M3330 (R600 Module + 3x DALI), or PCD3.M5560 for up to 4 DALI modules [...] 101653 . Minimal firmware version for the Manager is 1.16.42 (PCD1.M2) and 1.16.45 (PCD2.M5 and PCD3), see FAQ 101640 . Minimal version of PG5 for configuring a PCD3.T665¦T666 is PG5 2.0 SP2 (PG5 [...] ’. This change has been made in order to be compatible with the Windows 10 start menu that’s accept only one level of folder. Device configurator: PCD3.M3160: Power CPU with 512kByte program
to use a PLC with SD Flash for example PCD3.M3330 (R600 Module + 3x DALI), or PCD3.M5560 for up to 4 DALI modules [...] 101653 . Minimal firmware version for the Manager is 1.16.42 (PCD1.M2) and 1.16.45 (PCD2.M5 and PCD3), see FAQ 101640 . Minimal version of PG5 for configuring a PCD3.T665¦T666 is PG5 2.0 SP2 (PG5 [...] ’. This change has been made in order to be compatible with the Windows 10 start menu that’s accept only one level of folder. Device configurator: PCD3.M3160: Power CPU with 512kByte program