Documents Documents for Saia PCD QronoX General FAQ Documents concerning the IEC controller PCD3.M6893 Programmable with the Saia PCD® QronoX Engineering and Commissioning Suite. CPU LIOs Communication Modules I/O modules
Input/output modules for Saia PCD3 controllers Analogue output module, 4 channels, 8 bits, 0…10 V / 0…20 mA / 4...20 mA, jumper selectable (connector type A included)
01 0271 0022 fexible cable Note: If the bautrates isn't greater than 187,5 bautes (for ex. Profi S-Bus with PCD3.M3xx / PCD7.D7xx) you can use other more advantegeous cable, especially [...] 7.T160 D-Sub 9pin on PCD Port 2 on PCD3.M3 and M6 A=RxD /TxD-N green D pin 8 D B=RxD /TxD-P red D/ pin 3 /D Example for the port 3 of the PCD3.M5540 as Serial-S-Bus RS485 connection (Serial-S-Bus) between PCD3.M5540 port 3 (S-Net D-Sub used as RS485 Serial-S-Bus) and PCD2.M5540 port 2 (connector block X3
® COSinus-Systems PCD3.Mxxx0 and PCD2.M5xx0 - Texts < 4000 are writeable in runtime but PG5 recognizes if one of these texts has changed* - Texts >= 4000 are writeable in runtime PCD3.Mxx60 and PCD1.M2xx0 - Texts are configurable in the Build Options [...] 130, PCD1.M135, PCD2.M110, PCD2.M120 and PCD2.M150 The voltage of the battery is supervised. SBC advise to change the battery all 1 - 3 years. System with active battery supervision since
exist the following module types to be plugged into PCD I/O slot 0..3: CPU Family LON TP/FT-10 with PCD2/3.F240x module PCD1.M2xx0 Supported from hardware version F PCD2.M5xx0 Supported from hardware version D PCD3.M3xx0 PCD3.M5xx0 PCD3.M6xx0 Supported from hardware version H PCD3.Mxx60 Supported [...] link With the following PCDs it is not possible to configure the FTT10 communication modul in the device configurator PCD2.M5xx0/PCD3.M3xx0/PCD3.M5xx0/PCD3.M6xx0. However you can use it, if you
exist the following module types to be plugged into PCD I/O slot 0..3: CPU Family LON TP/FT-10 with PCD2/3.F240x module PCD1.M2xx0 Supported from hardware version F PCD2.M5xx0 Supported from hardware version D PCD3.M3xx0 PCD3.M5xx0 PCD3.M6xx0 Supported from hardware version H PCD3.Mxx60 Supported [...] link With the following PCDs it is not possible to configure the FTT10 communication modul in the device configurator PCD2.M5xx0/PCD3.M3xx0/PCD3.M5xx0/PCD3.M6xx0. However you can use it, if you
A "Bus Error" (which is indicated in the history of the PCD) indicates that the firmware was not able to execute an internal command (reading from the memory bus).
The M-Bus communication between the "Hydrometer M-Bus Receiver 868" (alternatively called "MB-Receiver") and the PCD2.F2710 has been analyzed and it was found that the device does not conform to the M-Bus specification (SN EN 13757-2). Therefore it can not be used together with the PCD2/3.F27x(0).