A. Nevertheless it is possible measuring the range 0..20 mA with the analogue input modules for PCD systems. Why do the SBC input modules have a range of 0..20 mA? One advantage of measuring the [...] Product Index Archive PCD6 Exxx E1xx General [...] . PCD6 Series (obsolete) Documentation
A. Nevertheless it is possible measuring the range 0..20 mA with the analogue input modules for PCD systems. Why do the SBC input modules have a range of 0..20 mA? One advantage of measuring the [...] Product Category Archive Programmable Controller PCD6: CPUs in 19 inch racks Exxx E [...] commercially available products. PCD
-Bus Data mode"). Saia PCD® COSinus based systems (PCD2.M480, PCD2.M5xx0 and PCD3) are not concerned. Reason The reason for this behavior is that the PCD/PCS does not correcly answer telegrams where [...] appears if the used firmware on the CPU does not support the "active and non ACK" filter for the S-Web alarming functionality (e.g. a PCD2.M150 with firmware 0D3). Symptom Instead of the [...] to the firmware supporting the according feature (see table below). System minimal FW PCS1.Cxxx 0E3 PCD1.M1x5 0E3 PCD2.M150 0E3
-Bus Data mode"). Saia PCD® COSinus based systems (PCD2.M480, PCD2.M5xx0 and PCD3) are not concerned. Reason The reason for this behavior is that the PCD/PCS does not correcly answer telegrams where [...] appears if the used firmware on the CPU does not support the "active and non ACK" filter for the S-Web alarming functionality (e.g. a PCD2.M150 with firmware 0D3). Symptom Instead of the [...] to the firmware supporting the according feature (see table below). System minimal FW PCS1.Cxxx 0E3 PCD1.M1x5 0E3 PCD2.M150 0E3
PCD3 or a PCD2.M5540 can be used. On the other hand there is no problem using the newer FT1.2 protocol which is supported by all RS232 interfaces of the PCD3 and the PCD2.M5540. Supported communication interfaces for EIB/KNX driver The table below shows the supported communication interfaces for connecting an EIB coupler to PCD3-, PCD2.M5540 and PCD1.M2120 systems. On other systems (e.g. PCD2.M170) all RS232 interfaces can be used for connecting an EIB/KNX coupler. CPU type PCD3.M5/6xx0 - PCD2.M5540 PCD3.Mxxx0 PCD3.Mxxx0 PCD2.M5540 PCD1.M
EPLAN P8 Product Macros for PCD2.M5xxx and PCD3 (August 2008)
. 1-ph. M-Bus Interf. 3-ph. M-Bus Interf [...] supply voltage pins 1L/2L and 3N/4N are inverted. This wrong label is present on the schema of the housing and directly on the pins. Problem When a PCD7.T162 produced before week 22 of 2011 [...] functionality is still the same but the 24V DC need to be connected to the pins 3N/4N and the 0V to 1L/2L. Remark Units of PCD7.T162 produced after 11/22 (30.05.2011) are correctly labelled and
COSinus FW 1.28.37 was released as maintenance version for the systems: - PCD1.M0xx0/M2xx0, PCD2.M4x60, PCD3.Mxx60, PCD3.M6880 and PCD3.T665/T666/T668 . In June 2017: the COSinus FW 1.28.16 was introduced into production for the systems: - PCD1.M0xx0/M2xx0, PCD2.M4x60, PCD3.Mxx60, PCD3.M6880 and PCD3.T665/T666/T668 . the BACnet and LonIP FW 1.28.16 was put into production [...] the following PCD's with 8 MB onboard firmware memory: PCD1.M0xx0/M2xx0, PCD2.M4x60, PCD3.Mxx60, PCD3.M6880 and PCD3.T665/T666/T668 The table below does show the hardware dependencies in
.F221 Workaround to use the RS-232 S-Bus communication over converters: For the PCD3: Instead of using a PCD3.F221, use the PCD3.F121. For PCD1.M2 or PCD2.M5: Instead of using a PCD2.F2xx0, use the PCD [...] specific M-Bus devices with the M-Bus modules PCD2/3.F27xx, the M-Bus driver may show the error "Missing value" even though all values are correctly returned by the device. Symptom When using the M-Bus modules PCD2/3.F27xx (with the framing protocol), the M-Bus driver may display the error "Missing value" even though all values are correctly returned. The problem concerns only few devices