: It's possible to connect SBC PCD's directly to the internet? (FAQ #102060) Yes it’s possible to connect a PCD directly [...] some protective measures. Information about protective measures can be found on the support hp If you need a PCD with cyber security levels SL3+ and based on ANSI ISA 62443 then [...] Why on the Saia PCD Supervisor, after an automatic logout or a restart of the server, the last displayed page is shown without the DeviceTemplate menu when logging in again? (FAQ #102057)
There is a problem on PG5 2.0 concerning the W745 module and Media mapping on PCD1M2120. The error message: Error 2021: _Device2.obj: Unresolved external symbol: S.IO.Slot0.StatusAnalogueInput appears after compiling.
There is a problem on PG5 2.0 device configurator concerning the W745 module and Media mapping on PCD1M2120. The error message: Error 2021: _Device2.obj: Unresolved external symbol: S.IO.Slot0.StatusAnalogueInput appears after compiling.
The first serie of PCD2.T814 modems with baseprint firmware < V1.09 have a problem when using the modem in the Hardware Settings for programming, for sending SMS and for DTMF at the same time.
It could happen that the position of linear encoders with high resolutions aren't read properly by the PCD2.H311 with hardware version older than A2.
Reading Input 5 to 8 of the PCD7.L100/L200 leads to a NAK response.
After an emergency stop the power of the driver must be switched off! You also have to stop the motion from the axis module H31x. This FAQ entry points out two ways to do that.
events please refer to www.saia-pcd.com. System Catalogue 2022/2023 A quick way to get an overview about [...] [47 MB] [47 MB] [47 MB] [47 MB] Security Upgrade for PCD Controllers New Firmwareversions offering improvements in IT-Security for PCD Controllers are ready to download. >> More Infos Connection of PCD controllers directly to the Internet Reduce the risk of potential
replacement product. In some applications the usage of a PCD1.M2xx0 could also be considered [...] 6) Until when can a PCD2.M120 be reparied? (FAQ #101482) The production of PCD2.M120 systems has been discontinued by the end of 2009. As possible replacement a PCD2.M150 or a PCD2.M5xx0 can be used. The PCD2.M120 can be repaired until the end of 2014 (five years after the phase
7.T160 D-Sub 9pin on PCD Port 2 on PCD3.M3 and M6 A=RxD /TxD-N green D pin 8 D B=RxD /TxD-P red D/ pin 3 /D Example [...] 3): PCD3.M5540 (D-Sub "S-Net", port 3) PCD2.M5540, X3, port2 equipped with a PCD7.F110 pin 3 terminal 2 pin 8 terminal 1 [...] diagnostic information of a PCD3.W745 on a PCD3.T760? (FAQ #101697) When the 4 channels analog carte PCD2.W745 is used on a