program with PG5 2.0.200 to a PCD1.M2xx0 or PCD3.Mxx60 the error message "Command not accepted: NAK response" can be returned by the downloader. Symptom When downloading a big program with PG5 2.0.200 to a PCD1.M2xx0 or PCD3.Mxx60 and in the option "Halt the PCD" before download is activated, the error message "Command not accepted: NAK response" can appear and the download is aborted. §Ix [...] On the patch 1 of the PG5 2.0.220 there is a error which does lead to the situation, that data’s which are defined by the user as ‘data transfer array’ where no more exchanged between the PCD3.T66x and
3.W525 • Correclty download and upload configuration of PCD2.M120 Ethernet RIO: • PCD goes in Halt when a data Transfer array is disabled Web Editor 5: • Update files: IMasterSaia5_15_02.jar, IMasterxx7_5_15_02.jar Bacnet: • Crash if tried to open a BACNet file which is deleted in Device Folder • For PCD3.Mxx60 and PCD1.M2xxx a donwnload of the program does not erase the whole [...] features of the SP1 (PG5 2.0.150) are: S-Web and FTP Server and IP Enhancements can be configured in the Device Configurator, see FAQ 101464 . Increased amount of available flags on a PCD3 or a
3.W525 • Correclty download and upload configuration of PCD2.M120 Ethernet RIO: • PCD goes in Halt when a data Transfer array is disabled Web Editor 5: • Update files: IMasterSaia5_15_02.jar, IMasterxx7_5_15_02.jar Bacnet: • Crash if tried to open a BACNet file which is deleted in Device Folder • For PCD3.Mxx60 and PCD1.M2xxx a donwnload of the program does not erase the whole [...] features of the SP1 (PG5 2.0.150) are: S-Web and FTP Server and IP Enhancements can be configured in the Device Configurator, see FAQ 101464 . Increased amount of available flags on a PCD3 or a
3.W525 • Correclty download and upload configuration of PCD2.M120 Ethernet RIO: • PCD goes in Halt when a data Transfer array is disabled Web Editor 5: • Update files: IMasterSaia5_15_02.jar, IMasterxx7_5_15_02.jar Bacnet: • Crash if tried to open a BACNet file which is deleted in Device Folder • For PCD3.Mxx60 and PCD1.M2xxx a donwnload of the program does not erase the whole [...] features of the SP1 (PG5 2.0.150) are: S-Web and FTP Server and IP Enhancements can be configured in the Device Configurator, see FAQ 101464 . Increased amount of available flags on a PCD3 or a
(PCD7.D776 Rev. 3) or by a hardware modification (PCD7.D776 Rev. 2). For updating the boot- and firmware version, please use the PCD8.D81W ( VTWIN) version 5.18 (or newer) which can be optained from [...] (port 0) of a PCD2.M110 (or a PCD2.M120) but not on the following systems: PCS1, PCD2.M150/M170/M480/M5xx0 or on a PCD3. Reason The PGU mode of recent PCD systems is no longer based on the P [...] .M150 and PCD2.M170: Modify your communication cable (Pin 6 should not be used, Pin 6 of PGU port =0). In the PCD program you need to add a "SASI Slave Mode D" with the parameters: RS 232, 9600, Parity, 7
(PCD7.D776 Rev. 3) or by a hardware modification (PCD7.D776 Rev. 2). For updating the boot- and firmware version, please use the PCD8.D81W ( VTWIN) version 5.18 (or newer) which can be optained from [...] (port 0) of a PCD2.M110 (or a PCD2.M120) but not on the following systems: PCS1, PCD2.M150/M170/M480/M5xx0 or on a PCD3. Reason The PGU mode of recent PCD systems is no longer based on the P [...] .M150 and PCD2.M170: Modify your communication cable (Pin 6 should not be used, Pin 6 of PGU port =0). In the PCD program you need to add a "SASI Slave Mode D" with the parameters: RS 232, 9600, Parity, 7
level Device Configurator: Support new IO modules - PCD2/3.W380 - PCD2.G200 - PCD7.W600 - PCD7.R610 Fupla Define groups and separators in the Page Navigator view Several [...] following new features and modifications have been implemented in the patch 1 for PG5 2.1.200: Project Manager - RIO and device names can now begin with a digit - In the TCP/IP setting table, device is [...] with PG5 V2.1.200, but not back again Once a project has been opened with PG5 V2.1.200, it is not possible to open it again with the previous versions. As this new version contains no major changes
of PG5 2.1 are upward compatible with PG5 V2.1.200, but not back again Once a project has been opened with PG5 V2.1.200, it is not possible to open it again with the previous versions. As this new [...] diagnostic information of a PCD3.W745 on a PCD3.T760? (FAQ #101697) When the 4 channels analog carte PCD2.W745 is used on a [...] ): Why does my PCD7.F7500 not work on my PCD2.M5540? (FAQ #101655) In some cases it is possible that a PCD7.F7500 is not
of PG5 2.1 are upward compatible with PG5 V2.1.200, but not back again Once a project has been opened with PG5 V2.1.200, it is not possible to open it again with the previous versions. As this new [...] diagnostic information of a PCD3.W745 on a PCD3.T760? (FAQ #101697) When the 4 channels analog carte PCD2.W745 is used on a [...] ): Why does my PCD7.F7500 not work on my PCD2.M5540? (FAQ #101655) In some cases it is possible that a PCD7.F7500 is not
level Device Configurator: Support new IO modules - PCD2/3.W380 - PCD2.G200 - PCD7.W600 - PCD7.R610 Fupla Define groups and separators in the Page Navigator view Several [...] following new features and modifications have been implemented in the patch 1 for PG5 2.1.200: Project Manager - RIO and device names can now begin with a digit - In the TCP/IP setting table, device is [...] with PG5 V2.1.200, but not back again Once a project has been opened with PG5 V2.1.200, it is not possible to open it again with the previous versions. As this new version contains no major changes