In the FPGA version HC3 of the PCD2.H110 there is a small bug: The LEDs for the CCO (Counter Controlled Output) and TCO (Timer Controlled Output) aren't working. However, CCO and TCO are working correctly, only the LEDs are affected. The bug is corrected in FPGA version HC4.
controller and a Saia PCD Supervisor Good to know To use the PCD7.LRxx-P5 programmable room controller you need minimum the versions: PG5: PG5.2.3.113 Version or higher [...] Documentation Room operation units DALI64 Lighting system PG5 2.3, DALI64 template project for programmable room controller PCD7.LRxx-P5 The following project templates can be used with PG5 2.3 or newer Install the template from Project-Configutator with "Restore project..." PG5 2.3, TR80 modbus template project for programmable room controller PCD
BACnet specific information The BTL certificate for: PCD7.LRL2, PCD7.LRS4, PCD7.LRS5 is stored here : App software for Android devices Firmware for PCD7.LRxx BACnet Room controllers Room operation units Good to know To use the PCD7.LRxx BACnet Room controller you need minimum the versions: PG5: PG5.2.2.200 Version or [...] 5 application program toggles cyclically a Flag where the Flag is mapped to a BACnet BI object ‘PCD-Input reference’ 2. If the BACnet stack is running, then the BACnet stack copies the ‘PCD-Input reference’ of
.06.2019 #102031 - On a PCD3.M6860 it’s possible to use BACnet on the Ethernet port ETH1 and/or on ETH2 [...] ? 08.12.2017 #102013 - Why after an download of a PG5 2.2.230 project to the PCD, where BACnet revision 14 is used, the application program on the PCD doesn’t work [...] ? 29.11.2017 #102008 - PG5 2.1 and PG5 2.2 with S-Bus communication library 2.7.370, why the S-Bus communication on the master PCD stops either after a certain time or
PCD4 conversion kit for connecting the PCD4 I/O level to a PCD2.M5xxx or PCD3.M3xxx/5xxx series CPU>
Saia PCD3 Wide Area Controller Modem PCD3.M2x30A4T5 with GSM/GPRS modem PCD3.M2330A4T1 with PSTN modem PCD3.M2330A4T3 with ISDN modem
Saia PCD3 Wide Area Controller Modem PCD3.M2x30A4T5 with GSM/GPRS modem PCD3.M2330A4T1 with PSTN modem PCD3.M2330A4T3 with ISDN modem
It is correct that the indication of a low battery will appears earlier due to more accurate prediction on a new Saia PCD® COSinus system than before on a PCD2/1.M1xx.
XX7_5_15_02.jar Datei behoben. PG5 2.1.300 oder höher enthält das überarbeitete Java Applet. Der Austauch des Applet wird im FAQ 101878 beschrieben Als vorläufige Lösung ist die Freigabe der IP- Adresse der PCD [...] In seltenen Fällen ist die Ether-S-Bus Kommunikation bei Programmen die aus PG5 2.0 oder 2.1.200 in die PG5 2.1.210 importiert wurden nach einem Rebuild All und anschließendem Download nicht mehr in [...] störbelasteten Umfeldern können diese Telegramme in den Störungen unter gehen. Abhilfe schafft die kontinuierliche Kommunikationsbibliothek V1.22A. Die Zustände der HNBE werden ständig zwischen der PCD und der
trace back a crash, a dump of the whole memory (SRAM, DRAM and FLASH) of a PCD can be done. This FAQ does apply to PCD1.M2, PCD2.M480, PCD2.M5xxx, PCD3 (including PCD3.Mxx60) and PCD [...] 5 2.1.210): This tool does open a small window which allow to define the device type and the destination folder where the dump files will be stored. The device field does show the PCD which is [...] : - RUN_DUMP_PCD1M2xx0.bat for PCD1.M2xx0 - RUN_DUMP_PCD3Mxxx0.bat for PCD2.M5xx0 and PCD3 systems - RUN_DUMP_PCD3Mxx6x.bat for PCD3.Mxx60 (fast CPU) systems After a successful dump a new