PCD7.F1xxS Serial interface modules Documentation Good to know The PCD7.F1xxS modules with hardware version A can not be used on non Saia PCD® COSinus systems (PCD1.M1xx, PCD2.M1xx, PCS1), see FAQ 101743 . The PCD7.F1xx modules will be replaced by the fully compatible PCD7.F1xxS modules (fully [...] Product Category Programmable controller PLC Accessories Communication Modules PCD
The product line PCD7.D8xx has been discontinued. As replacement it is recommended to use a VGA S-Web PCD7.D410V panel and taking advantage of the integrated WebServer of the PCD. PCD7 / D8xx Why has the VT Win project such a [...] bigger (100-200MBytes). Problem The size of the project increase after storing to a really hughe size. Reason If unicode fonts are used which are not present in the PC
On a Profi S-Bus network when PCD7.D76_ terminals are connected to PCD3.Mxxx or PCD2.M480 PLC's over Profi S-Bus, the terminal loses the communication after some time and get even frozen. This problem is corrected in the new boot, FW and driver. The PCD8.D81 V 5.09 is needed , the attached files have to be copied in it (see procedure below). It is also necessary to update the PCD3.Mxxx and PCD2.M480 FW with the version PCD3.Mxxx_023.blk / PCD2.M480_$27 or newer! Ask the PCD technical support or your representation for it!
This firmware is used in the PCD production and the PCD's are shipped with this firmware. Do use at least the PG5 firmware downloader version 2.1.311 or newer (included in PG5 patch 2.1.311 or newer) to prevent the loading of the FW 1.24.xx to a not compatible PCD.
FW for the pWeb-Panel PCD7.D4xxxT5. This firmware does support the module PCD7.R610 Do use at least the PG5 firmware downloader version 2.1.311 or newer (included in PG5 patch 2.1.311 or newer) to prevent the loading of the FW 1.24.xx to a not compatible PCD.
This firmware could be used as maintenance firmware for PCD's with 8 MB firmware memory. Do use at least the PG5 firmware downloader version 2.1.311 or newer (included in PG5 patch 2.1.311 or newer) to prevent the loading of the FW 1.24.xx to a not compatible PCD.
least the PG5 firmware downloader version 2.1.311 or newer (included in PG5 patch 2.1.311 or newer) to prevent the loading of the FW 1.24.xx to a not compatible PCD. Firmware 1 [...] used as destination. STXMX / SRXMX instructions are working correctly. I/O modules: - PCD2.G200: temperature is correctly calculated when Ni100 L&S is selected - PCD2/3.W380: support for [...] SASI mode (MC2) does not work on PCD2.M5xx0 port 2 If the a Smart RIO or Smart RIO manager is disabled with the tag, the manager still sends the configuration to the RIO The Program Restore when
PCD7.D1000 Embedded nano-browser (eDisplay for PCD2.M5xx0) Documentation Firmware Good to know There is a "Getting started with eDisplay" example available in the Getting Started section for PG5 2.0. For downloading the firmware of a PCD [...] /IP settings of the PCD2.M5 CPU with the eDisplay (PCD7.D3100E), when are the new TCP/IP settings are activated? (FAQ #101168)
.4 (R.H. sensor) will be adapted accordingly in the next release. 4.2.3 Temperature sensor Temperature sensor used in PCD7.D290 is active and supplies as output a voltage of 10.0 mV/°C; this [...] accuracy value: ± 1°C (± 1.5°C in the worse case) 4.2.4 R.H. sensor R.H. sensor used in PCD7.D290 is capacitive and supploes as output a capacity in the range 161.6 pF at 0% R.H. and 193.1 p [...] (PCD7.D23x and PCD7.D290) are connected to a RS 485 port (Bus terminal) of a PCDx.F2xx module, the communication doesn't work. Only one of the displays is available, the other one(s) is (are) not accessible
7.D23x are compatible with PG5 1.4.200. Symptom When programming a PCD with a PCD7.D23x (a pilot- or prototype version) with PG5 1.4.200, it may happen that the display jumps back to the root [...] protocol mode (RS485, "FTP" mode) on all PCD3 RS 485 ports (also on ports F2xx) must TEMPORARY be done with a special setting in the Advanced section of the SW Settings of the PG5. For the [...] When an element is configured as Integer with the format ##### (without dot) the value of the register is wrongly displayed on the terminal. This is a FW bug in the actual version of the PCD3.M_ and PCD2