security please contact your existing SBC account manager The Security upgrade was introduced since PG5® version 2.1.200 and COSinus operating system version 1.22.10 for PCD controllers and MB [...] upgrade for Saia PCD® controllers SBC takes security very seriously and we know that cyber security is a top concern for our customers and will continue to assess and test our devices to ensure they are [...] /30-004 Recommended VPN routers) Caution: Via the internet accessible PCD controllers have to be separated from the internet by means of a firewall and a protected virtual private network
The production of PCD2.M120 systems has been discontinued by the end of 2009. As possible replacement a PCD2.M150 or a PCD2.M5xx0 can be used.
The PCD1.M120 and PCD1.M130 have been discontinued by the end of 2006 and the repair service has been stopped by the end of 2011 after the usual 5 years of guaranteed repair service. The mechanically identical PCD1.M125 or PCD1.M135 could be used as replacement product. In some applications the usage of a PCD1.M2xx0 could also be considered.
found here Tools needed on the Saia PCD Supervisors Optimizer Unitary Tools - jar modules supporting PCD supervisor version 4.13u2 can be loaded from here Optimizer Unitary [...] Product Category Programmable room controller UN-RxxxNMC: Saia PCD Supervisor programmable room controller [...] UN-RxxxNMC With Saia PCD Supervisor freely programmable room controller
found here Tools needed on the Saia PCD Supervisors Optimizer Unitary Tools - jar modules supporting PCD supervisor version 4.13u2 can be loaded from here Optimizer Unitary [...] Product Index Honeywell devices UN-RxxxNMC: Saia PCD Supervisor programmable room controller [...] UN-RxxxNMC With Saia PCD Supervisor freely programmable room controller
Tools Good to know The PCD4.U100 must be used with a PCD4.N2x0 with hardware version "B" or newer, see FAQ 101720 . The PCD4.U100 upgrade kit can be used in order to replace the CPU of a PCD4 installation by a PCD3 or a PCD2.M5 (while keeping the PCD4 I/Os). The PCD4 family has been discontinued and is no longer available. Please refer to FAQ 101098 for more [...] of the PCD4.N2x0 to be used with a PCD4.U100? (FAQ #101720) The minimal hardware version of the PCD4 power supply
Tools Good to know The PCD4.U100 must be used with a PCD4.N2x0 with hardware version "B" or newer, see FAQ 101720 . The PCD4.U100 upgrade kit can be used in order to replace the CPU of a PCD4 installation by a PCD3 or a PCD2.M5 (while keeping the PCD4 I/Os). The PCD4 family has been discontinued and is no longer available. Please refer to FAQ 101098 for more [...] of the PCD4.N2x0 to be used with a PCD4.U100? (FAQ #101720) The minimal hardware version of the PCD4 power supply
7.T160 D-Sub 9pin on PCD Port 2 on PCD3.M3 and M6 A=RxD /TxD-N green D pin 8 D B=RxD /TxD-P red D/ pin 3 /D Example [...] 3): PCD3.M5540 (D-Sub "S-Net", port 3) PCD2.M5540, X3, port2 equipped with a PCD7.F110 pin 3 terminal 2 pin 8 terminal 1 [...] inverted. This wrong label is present on the schema of the housing and directly on the pins. Problem When a PCD7.T162 produced before week 22 of 2011 (30.05.2011) has a 24V DC supply voltage
. PCD1.T240 Remote I/O for S-Bus (obsolete) Documentation Good to know Not all PCD2.xxx modules are supported by the PCD1.T240 firmware. Modules that can be used: PCD2.E11x, A4xx, A2xx, W1xx, W2xx, W4xx. [...] Product Index Archive PCD1 Txxx General
PCD6.E100, PCD6.E610, PCD6.E611 or PCD6.A350 (FAQ #100264) These 4 digital I/O cards have all an address [...] . Nevertheless it is possible measuring the range 0..20 mA with the analogue input modules for PCD systems. Why do the SBC input modules have a range of 0..20 mA? One advantage of measuring the [...] the used power supply does not have the +/-15V the analogic carts can not work. With the PCD4/6.N200 supply it is not possible to use analogic cards. You will need the PCD4/6.N210 supply