inputs of a module PCD2/3.W525 could perturbate an other input of the same module Module PCD2/3.W525 are not designed as other analog input modules (as PCD2/3.W340 or W200 for example). Particularities [...] correctly. Solution This problem is solved with hardware version A or C and newer of the PCD2.W6x5 or PCD3.W6x5 respectively. What is the signification of the I/O words of a PCD2/3.W525 module? (FAQ #101552) When configuring a W525 module using
inputs of a module PCD2/3.W525 could perturbate an other input of the same module Module PCD2/3.W525 are not designed as other analog input modules (as PCD2/3.W340 or W200 for example). Particularities [...] correctly. Solution This problem is solved with hardware version A or C and newer of the PCD2.W6x5 or PCD3.W6x5 respectively. What is the signification of the I/O words of a PCD2/3.W525 module? (FAQ #101552) When configuring a W525 module using
address 240). On all other slots the modules work correctly. Solution This problem is solved with hardware version A or C and newer of the PCD2.W6x5 or PCD3.W6x5 respectively [...] PCD2.W745 is used on a PCD3.T760 RIO module 6 registers are available on the master station. It is important to know that the 2 first registers contain the diagnostic bits of the 4 inputs channels [...] : There's an error in allocating the address mapping of the Device Configurator in PG5 2.0.200 (SP2) for this analog card PCD3.W745. Solution: This problem will be solved in PG5.2
inputs of a module PCD2/3.W525 could perturbate an other input of the same module Module PCD2/3.W525 are not designed as other analog input modules (as PCD2/3.W340 or W200 for example). Particularities [...] correctly. Solution This problem is solved with hardware version A or C and newer of the PCD2.W6x5 or PCD3.W6x5 respectively. What is the signification of the I/O words of a PCD2/3.W525 module? (FAQ #101552) When configuring a W525 module using
4.W1xx Analogue modules (obsolete) Documentation Good to know PCD4.W110 has been a configured version including standard range modules, please order 1x PCD4.W100, 1x PCD7.W101 and 1x PCD7.W200 to get a full replacement with four inputs 0..10V and one output 0..10V. PCD4.W112 has been a configured version including standard range modules, please order 1x PCD4.W100, 1x PCD7.W101 and 2x PCD7.W200 to get a full replacement with four inputs 0..10V and two outputs 0..10V.
. PCD4.W1xx Analogue modules (obsolete) Documentation Good to know PCD4.W110 has been a configured version including standard range modules, please order 1x PCD4.W100, 1x PCD7.W101 and 1x PCD7.W200 to get a full replacement with four inputs 0..10V and one output 0..10V. PCD4.W112 has been a configured version including standard range modules, please order 1x PCD4.W100, 1x PCD7.W101 and 2x PCD7.W200 to get a full replacement with four inputs 0..10V and two outputs 0..10V.
inputs of a module PCD2/3.W525 could perturbate an other input of the same module Module PCD2/3.W525 are not designed as other analog input modules (as PCD2/3.W340 or W200 for example). Particularities [...] point with a good ground connection. This star point must be connected with a wire as short and thick as possible to pin 22/23 (for PCD1) or pin 23/24 (for PCD2) respectively [...] correctly. Solution This problem is solved with hardware version A or C and newer of the PCD2.W6x5 or PCD3.W6x5 respectively
inputs of a module PCD2/3.W525 could perturbate an other input of the same module Module PCD2/3.W525 are not designed as other analog input modules (as PCD2/3.W340 or W200 for example). Particularities [...] connected with a wire as short and thick as possible to pin 22/23 (for PCD1) or pin 23/24 (for PCD2) respectively [...] correctly. Solution This problem is solved with hardware version A or C and newer of the PCD2.W6x5 or PCD3.W6x5 respectively
at https://www.promosnt.ch/en/contact Saia PCD® Supervisor , our powerful building monitoring-and-management solution, replaces Saia Visi.Plus and offers a wide range of additional [...] ://www.promosnt.ch/en/contact Saia PCD® Supervisor , our powerful building monitoring-and-management solution, replaces Saia Visi.Plus and offers a wide range of additional functions and enhancements. Retain your Engineering [...] Chapter: 7.2.11.4 The following info are needed: A screenshot about the License ID and the Dongle ID shown with red arrow. The Promos.key file . The order form which tells the details
at https://www.promosnt.ch/en/contact Saia PCD® Supervisor , our powerful building monitoring-and-management solution, replaces Saia Visi.Plus and offers a wide range of additional [...] ://www.promosnt.ch/en/contact Saia PCD® Supervisor , our powerful building monitoring-and-management solution, replaces Saia Visi.Plus and offers a wide range of additional functions and enhancements. Retain your Engineering [...] Chapter: 7.2.11.4 The following info are needed: A screenshot about the License ID and the Dongle ID shown with red arrow. The Promos.key file . The order form which tells the details