firmware. Solution At the moment the dynamic space has to be defined >=1000 and Timeout -> TS-Delay -> TN-Delay -> Break length ) If you want to disable the "Secure S-Bus Data mode" If you [...] ) Why does the FBox "SASI S-Bus Extended" not work (for assigning a gateway master port)? (FAQ #101399) There are several reasons to use the FBox "SASI S-Bus Extended" (see FAQ 101400). But there is a limitation that it is not possible to use this FBox for re-assigning a port as Gateway master port on Saia PCD® COSinus
Zum Einschalten des PCD8.K120 Profi-S-Link Adapter müssen Sie den Profi-S-Bus von den entsprechenden Port für den "Profi-S-Bus"-Ordner der PG5-Hardware-Einstellungen und Sie aktivieren müssen die Hardware-Einstellungen an die PCD Downolad.[autotranslated]
(Quellbetrieb) - 6 Relaisausgänge (Schliesser) 230 VAC / 30 VDC, 4 A ( ohmsche Last ) - 4 Relaisausgänge (Wechsler) 230 VAC / 30 VDC, 4 A ( ohmsche Last ) - 1 Schnittstelle RS-485 S-Bus und Modbus [...] (Quellbetrieb) - 6 Relaisausgänge (Schliesser) 230 VAC / 30 VDC, 4 A ( ohmsche Last ) - 4 Relaisausgänge (Wechsler) 230 VAC / 30 VDC, 4 A ( ohmsche Last ) - 1 Schnittstelle RS-485 S-Bus und Modbus [...] (Quellbetrieb) - 4 Relaisausgänge (Wechsler) 230 VAC / 30 VDC, 4 A ( ohmsche Last ) - 1 Schnittstelle RS-485 S-Bus und Modbus, Modbus wird ab FW 1.08.04 unterstützt
CPU base units for 4 plug-in I/O modules - Saia PCD3.M3 series PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 128 KByte user program, backup with on-board Flash memory, clock (RTC), USB port for PG5, up to 64 I/O, 2 interrupt inputs, RS-485 for Profi-S-Net or S-Bus
CPU base units for 4 plug-in I/O modules - Saia PCD3.M3 series PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 512 KByte user program, 128 MByte user Flash memory with file system, clock (RTC), USB port for PG5, up to 64 I/O, 2 interrupt inputs, RS-485 for Profi-S-Net or S-Bus
CPU base units for 4 plug-in I/O modules - Saia PCD3.M3 series PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 512 KByte user program, backup with on-board Flash memory, clock (RTC), USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-485 for Profi-S-Net or S-Bus
CPU base units for 4 plug-in I/O modules - Saia PCD3.M3 series PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 512 KByte user program, 128 MByte user Flash memory with file system, clock (RTC), USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-485 for Profi-S-Net or S-Bus
möglich, dass einige der S-Bus Telegramme welche vom PCD S-Bus-Master zum S-Bus Slave über RS485 übertragen werden, fehlerhaft sind, und der S-Bus Slave die S-Bus Telegramm vom Master verwirft. Dies [...] Ein Firmware-Update der PCD, welche als S-Bus Master agiert, mit einer Firmware 1.28.34 oder neuer löst das Problem. Symptome Programmierbaren PCD's, die als S-BUS Master über RS [...] . PCD1 / E-Line Warum funktioniert die RS-485 S-Bus
Diese Fehlermeldung kann zwei Gründe haben; einer infolge einer TCP-Verbindung, die vom Server der geschlossen worden ist, wenn die S-Bus-Verbindung nicht ordnungsgemäß funktioniert.[autotranslated]
In Firmware 03 b und 03C wird ein S-Bus-broadcast-Telegramm die Kommunikationsschnittstelle blockiert, bis zum nächsten Neustart der PCD.[autotranslated]