saia-pcd.com
239
Channel
MP Single
–
Clr
Err―
–
ClrFBox
Err―
ref:Channel
MP Air
―En
Err―
–
Res
Sen―
―Pos
SEr―
Pos―
Me1―
Me2―
Me3―
DAd ????
ref:Channel
MP BS
―En
Err―
–
Res
Opn―
–
O/C
Cls―
–
Tst
MTr―
MOv―
DTr―
DTm―
Alm―
OEm―
Tst―
DAd ????
ref:Channel
MP VAV
―En
rr
–
Res
V%―
― Vol
Vol―
― Opn
Sen―
― Cls
Pos―
Me1―
Me2―
Me3―
DAd ????
ref:Channel
MP Linear
―En
Err―
–
Res
Sen―
― Pos
SEr―
Pos―
Me1―
Me2―
Me3―
DAd ????
ref:Channel
MP Air
―En
Err―
–
Res
Sen
―Pos
SEr―
Pos
Me1―
Me2―
Me3―
DAd ????
ref:Channel
MP 6-way
―En
Err―
–
Res
Sen―
― Cool
SEr―
― Heat
Pos―
Me1―
Me2―
Me3―
DAd ????
ref:Channel
MP EPIV20
―En
Err
–
Res
V%
― Vol
Vol
― Opn
Sen―
― Cls
Pos―
Me1―
Me2―
Me3―
DAd ????
ref:Channel
MP THCV sensor
―En
Err―
Tmp―
Hum
CO2
VOC―
VOCg―
VOCt―
Flush―
Aln―
Dln―
ErrT―
ErrH―
ErrC―
ErrV―
DAd ????
ref:Channel
MP PEEK
―En
Err
Val
DAd ????
ref:Channel
MP POKE
―En
Err
―Val
DAd ????
ref:Channel
MP PTH
―En
Err―
–
Res
Wrn―
Def―
Hum―
Prs―
Tmp―
Sen―
SEr―
DAd ????
ref:Channel
MP UST 3
―En
Err―
―Vlt
Sen―
―Rl1
SEr―
―Rl2
U1―
―Rl3
U2―
U3―
In1―
In2―
In3―
DAd ????
ref:Channel
MP Generic
―En
Error
DAd ????
ref:Channel
MP PEEK
―En
Err
Val
DAd ????
ref:Channel
MP POKE
―En
Err
―Val
DAd ????
1
SBC software
3
SBC S-Web technology
2
Communication &
Interaction
Communication & Interaction
4
Room automation
MP Bus |
Function modules (FBox)
All Belimo MP drives can exchange data with the PCD application program via a suitable FBox from the MP Bus FBox library. The master
communication FBox must be positioned once at the start of the application program. It controls the communication and fault recogni-
tion and creates ways of addressing the MP drives available for commissioning and service. Some MP drives also have an input for con-
necting sensors. R: Temperature sensor NI1000, PT1000…, U:voltage 0–32 V or 0–10 V and DI: Potential-free contact.
Type/performance categories
Sensors
MP Bus FBox
Communication drivers
Ventilation applications
Damper drives with no safety function:
LM24A-MP (5 Nm), NM24A-MP (10 Nm), SM24A-MP (20 Nm),
GM24A-MP (40 Nm)
Damper drives with safety function:
TF24-MFT (2 Nm), LF24-MFT2 (4 Nm), SF24A-MP (20 Nm)
Linear damper drives:
LH24A-MP100 / 200 / 300 (150 N), SH24A-MP100 / 200 / 300 (450 N)
Damper drives rotary:
LU24A-MP (3 Nm)
R, U, DI
Safety applications
Drives for fire dampers:
BF24TL-T-ST (18 Nm), BFG24TL-T-ST (11 Nm)
Gateway for conventional fire damper drives:
BKN230-24-C-MP
Thermal
element
Room and system applications
VAV compact controller:
LMV-D3-MP (5 Nm), NMV-D3-MP (10 Nm), SMV-D3-MP (20 Nm)
VAV compact controller linear:
LHV-D3-MP (150 N)
VAV universal controller:
VRP-M
R, U, DI
Water applications
Lift drives with no emergency function:
LV24A-MP-TPC (500 N), LVC24A-MP-TPC (500 N), NV24A-MP-TPC
(1000 N), NVC24A-MP-TPC (1000 N), SV24A-MP-TPC (1500 N), SVC24A-MP-TPC (1500 N), EV24A-MP-TPC
(2500 N)
Lift drives with emergency function:
NVK24A-MP-TPC (1000 N), NVKC24A-MP-TPC (1000 N),
AVK24A-MP-TPC (2000 N), adjustable closing point, adjustable emergency setting
Drives for control ball valve with no emergency function:
LR24A-MP (5 Nm), NR24A-MP (10 Nm),
SR24A-MP (20 Nm)
Drives for control ball valve with emergency function:
TRF24-MFT* (2 Nm), LRF24-MP (4 Nm),
NRF24A-MP (10 Nm), SRF24A-MP (20 Nm)
Drives for butterfly valves with no emergency function:
SR24A-MP-5 (20 Nm), GR24A-MP-5/-7 (40 Nm)
R, U, DI
Water applications
Drives for 6-way control ball valve:
LR24A-MP (5 Nm), NR24A-MP (10 Nm)
Electronic pressure-independent control ball valve (EPIV):
P6…W…E-MP*
R, U, DI
U, DI
Room sensors
Room combi-sensor, depending on design with temperature,
CO
2, VOC and relative humidity:
MS24A R…
MPX
R, DL,
U (0–10 V)
Generic data transfer
For reading and transmitting data points not contained in the device-specific FBox. This FBox is used as a
functional extension for MP Bus FBoxes and can only be used with a device FBox specific to that device or a
generic device FBox.
Third party devices
FBoxes are available for the following third party MP Bus devices:
PTH sensor from wmag AG, Switzerland,
UST-3, UST-5 from wmag AG, Switzerland.
Each MP Bus device can also be connected via generic devices and peek/poke FBoxes in PCD application
programs.
* only active sensors and switches can be connected