BIM-Objects for PLCs (Programmable Language Controller) - PCD3
-
IEC Controllers - programmable with QRONOX
BIM - PCD3.M6893 IEC-Controller
Tutorial | PCD3.M6893 | BIM - PCD3.M6893 IEC-Controller |
Saia PCD3.M6893 - IEC Controller
The most recent cyber security level (ANSI ISA 62443 – SL3/SL4) enables the use in mission critical and IoT / Cloud applications.
Main features
- PCD3 controller without battery
- 1 × GByte RAM and 4 GByte Flash for operating system and user program
- 1 × Socket for user data micro-SD card, max. 32 GByte
- 2 × Ethernet
- 1 × RS-485
- 1 × socket for PCD7.F1xxS communication modules
- 1 × CAN galvanic separated
- 1 × USB Device port for programming and service
- 1 × USB host 2 × interrupt inputs
- 1 × watch dog relay
- extendable up to 1023 I/O
Supported PCD3 - I/O Modules:
- Connector for I/O Extension PCD3.C200
- Starting with firmware 0.0.0.281: PCD3.Ax, …Ex, …W3x5, …W6x5
PDS - xlsx | Download | ||||
Revit-file - .rfa - Revision: a | .zip | 0.30 MB | Download | ||
CREO-export - .sat | .zip | 0.03 MB | Download | ||
Step-file - .step | .zip | 0.02 MB | Download | ||
Step-file - .stp | .zip | 0.02 MB | Download |
CPU base units for 4 plug-in I/O modules - Saia PCD3.M6 series
BIM - PCD3 redundant processor unit
Tutorial | PCD3.M6880 | BIM - PCD3 redundant processor unit |
Standby Controller
CPU base units for 4 plug-in I/O modules - Saia PCD3.M6 series
PCD3 Standby processor unit with 2 Ethernet TCP/IP and Co-processor for Standby operation, web and FTP server, file system, CPU with 2 MByte user program, 1 MByte SRam extension memory, 128 MByte user Flash memory with file system, clock (RTC), data protection 1-3 years, USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-485 for Profi-S-Net/MPI/S-Bus
PDS - xlsx | 0.31 MB | Download | |||
Revit-file - .rfa - Revision: - | .zip | 0.64 MB | Download | ||
CREO-export - .sat | .zip | 0.22 MB | Download | ||
STEP-file - .step | .zip | 0.54 MB | Download | ||
STP-file - .stp | .zip | 0.23 MB | Download | ||
DXF-file - .dxf | .zip | 0.13 MB | Download | ||
IFC-file - .ifc | .zip | 0.34 MB | Download | ||
IGES-file - .iges | .zip | 0.24 MB | Download | ||
RHINO-file - .3dm | .zip | 0.56 MB | Download | ||
X3D-file - .x3d | .zip | 0.09 MB | Download | ||
DS - 34-008 ENG | 1.39 MB | Download | |||
DS - 34-008 FRA | 1.40 MB | Download | |||
DS - 34-008 GER | 1.41 MB | Download | |||
DS - 34-008 ITA | 1.40 MB | Download | |||
Manual - 26-789 ENG | 16.08 MB | Download | |||
Manual - 26-789 FRA | 15.39 MB | Download | |||
Manual - 26-789 GER | 17.79 MB | Download | |||
Manual - 26-789 ITA | 15.01 MB | Download | |||
IGS-file - .igs | .zip | 0.24 MB | Download | ||
Manual: 27-645_ENG03 | 6.04 MB | Download |
BIM - PCD3 processor unit
Tutorial | PCD3.M6860 | BIM - PCD3 processor unit |
CPU base units for 4 plug-in I/O modules - Saia PCD3.M6 series
PCD3 processor unit with 2 Ethernet TCP/IP, web and FTP server, file system, CPU with 2 MByte user program, 1 MByte SRam extension memory, 128 MByte user Flash memory with file system, clock (RTC), data protection 1-3 years, USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-485 for Profi-S-Net/MPI/S-Bus
PDS - xlsx | 0.31 MB | Download | |||
Revit-file - .rfa - Revision: - | .zip | 0.65 MB | Download | ||
CREO-export - .sat | .zip | 0.21 MB | Download | ||
STEP-file - .step | .zip | 0.53 MB | Download | ||
STP-file - .stp | .zip | 0.23 MB | Download | ||
DXF-file - .dxf | .zip | 0.13 MB | Download | ||
IFC-file - .ifc | .zip | 0.32 MB | Download | ||
IGES-file - .iges | .zip | 0.24 MB | Download | ||
IGS-file - .igs | .zip | 0.24 MB | Download | ||
DS - 34-007 ENG | 0.37 MB | Download | |||
DS - 34-007 FRA | 0.37 MB | Download | |||
DS - 34-007 GER | 0.37 MB | Download | |||
DS - 34-007 ITA | 0.37 MB | Download | |||
Manual - 26-789 ENG | 16.08 MB | Download | |||
Manual - 26-789 FRA | 15.39 MB | Download | |||
Manual - 26-789 GER | 17.79 MB | Download | |||
Manual - 26-789 ITA | 15.01 MB | Download | |||
Leaflet: 35-015 | 0.10 MB | Download | |||
RHINO-file - .3dm | .zip | 0.55 MB | Download | ||
X3D-file - .x3d | .zip | 0.09 MB | Download |
BIM - PCD3 processor unit
Tutorial | PCD3.M6560 | BIM - PCD3 processor unit |
CPU base units for 4 plug-in I/O modules - Saia PCD3.M6 series
PCD3 processor unit with Profibus DP Master and Ethernet TCP/IP, web and FTP server, file system, CPU with 2 MByte user program, 1 MByte SRam extension memory, 128 MByte user Flash memory with file system, clock (RTC), data protection 1-3 years, USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-232, RS-485 for Profi-S-Net/MPI/S-Bus
PDS - xlsx | 0.31 MB | Download | |||
Revit-file - .rfa - Revision: - | .zip | 0.74 MB | Download | ||
CREO-export - .sat | .zip | 0.23 MB | Download | ||
STEP-file - .step | .zip | 0.58 MB | Download | ||
STP-file - .stp | .zip | 0.25 MB | Download | ||
DXF-file - .dxf | .zip | 0.20 MB | Download | ||
IFC-file - .ifc | .zip | 0.50 MB | Download | ||
IGES-file - .iges | .zip | 0.27 MB | Download | ||
IGS-file - .igs | .zip | 0.27 MB | Download | ||
DS - 31-668 ENG | 0.19 MB | Download | |||
DS - 31-668 FRA | 0.19 MB | Download | |||
DS - 31-668 GER | 0.19 MB | Download | |||
DS - 31-668 ITA | 0.19 MB | Download | |||
Manual - 26-789 ENG | 16.08 MB | Download | |||
Manual - 26-789 FRA | 15.39 MB | Download | |||
Manual - 26-789 GER | 17.79 MB | Download | |||
Manual - 26-789 ITA | 15.01 MB | Download | |||
RHINO-file - .3dm | .zip | 0.69 MB | Download | ||
X3D-file - .x3d | .zip | 0.14 MB | Download | ||
Leaflet: 35-014 | 0.10 MB | Download |
BIM - PCD3 processor unit with CAN bus
Tutorial | PCD3.M6360 | BIM - PCD3 processor unit with CAN bus |
CPU base units for 4 plug-in I/O modules - Saia PCD3.M3 series
PCD3 processor unit with CAN bus and Ethernet TCP
Revit-file - .rfa - Revision: - | .zip | 0.86 MB | Download | ||
CREO-export - .sat | .zip | 0.25 MB | Download | ||
STEP-file - .step | .zip | 0.63 MB | Download | ||
STP-file - .stp | .zip | 0.28 MB | Download | ||
DXF-file - .dxf | .zip | 0.30 MB | Download | ||
IFC-file - .ifc | .zip | 0.74 MB | Download | ||
IGES-file - .iges | .zip | 0.29 MB | Download | ||
IGS-file - .igs | .zip | 0.29 MB | Download | ||
RHINO-file - .3dm | .zip | 0.81 MB | Download | ||
X3D-file - .x3d | .zip | 0.20 MB | Download | ||
DS - 34-011 ENG | 0.28 MB | Download | |||
DS - 34-011 FRA | 0.28 MB | Download | |||
DS - 34-011 GER | 0.28 MB | Download | |||
DS - 34-011 ITA | 0.28 MB | Download | |||
Manual - 26-789 ENG | 16.08 MB | Download | |||
Manuel - 26-789 FRA | 15.39 MB | Download | |||
Handbuch - 26-789 GER | 17.79 MB | Download | |||
Manuale - 26-789 ITA | 15.01 MB | Download | |||
Leaflet: 35-014 | 0.10 MB | Download | |||
Manual: 26-839 - ENG | 1.61 MB | Download |
CPU base units for 4 plug-in I/O modules - Saia PCD3.M5 series
BIM - PCD3 processor unit
Tutorial | PCD3.M5560 | BIM - PCD3 processor unit |
Saia PCD3 modular programmable controllers
PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 2 MByte user program, 1 MByte SRam extension memory, 128 MByte user Flash memory with file system, clock (RTC), data protection 1-3 years, USB port for PG5, up to 1024 I/O, 2 interrupts, RS-232, 2x RS-485 for Profi-S-Net/MPI/S-Bus
PDS - xlsx | 0.31 MB | Download | |||
Revit-file - .rfa - Revision: - | .zip | 0.60 MB | Download | ||
CREO-export - .sat | .zip | 0.23 MB | Download | ||
STEP-file - .step | .zip | 0.58 MB | Download | ||
STP-file - .stp | .zip | 0.25 MB | Download | ||
DXF-file - .dxf | .zip | 0.20 MB | Download | ||
IFC-file - .ifc | .zip | 0.50 MB | Download | ||
IGES-file - .iges | .zip | 0.27 MB | Download | ||
IGS-file - .igs | .zip | 0.27 MB | Download | ||
DS - 31-663 ENG | 0.36 MB | Download | |||
DS - 31-663 FRA | 0.37 MB | Download | |||
DS - 31-663 GER | 0.37 MB | Download | |||
DS - 31-663 ITA | 0.38 MB | Download | |||
Manual - 26-789 ENG | 16.08 MB | Download | |||
Manual - 26-789 FRA | 15.39 MB | Download | |||
Manual - 26-789 GER | 17.79 MB | Download | |||
Manual - 26-789 ITA | 15.01 MB | Download | |||
RHINO-file - .3dm | .zip | 0.69 MB | Download | ||
X3D-file - .x3d | .zip | 0.14 MB | Download |
BIM - PCD3 processor unit
Tutorial | PCD3.M5540 | BIM - PCD3 processor unit |
Saia PCD3 modular programmable controllers
PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 1 MByte user program, backup option with PCD7.R5xx/R610 Flash card, clock (RTC), data protection 1-3 years, USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-232, 2x RS-485 for Profi-S-Net/MPI/S-Bus
PDS - xlsx | 0.31 MB | Download | |||
Revit-file - .rfa - Revision: - | .zip | 0.59 MB | Download | ||
CREO-export - .sat | .zip | 0.23 MB | Download | ||
STEP-file - .step | .zip | 0.58 MB | Download | ||
STP-file - .stp | .zip | 0.25 MB | Download | ||
DXF-file - .dxf | .zip | 0.20 MB | Download | ||
IFC-file - .ifc | .zip | 0.50 MB | Download | ||
IGES-file - .iges | .zip | 0.27 MB | Download | ||
IGS-file - .igs | .zip | 0.27 MB | Download | ||
DS - 31-662 ENG | 0.36 MB | Download | |||
DS - 31-662 FRA | 0.37 MB | Download | |||
DS - 31-662 GER | 0.36 MB | Download | |||
DS - 31-662 ITA | 0.37 MB | Download | |||
Manual - 26-789 ENG | 16.08 MB | Download | |||
Manual - 26-789 FRA | 15.39 MB | Download | |||
Manual - 26-789 GER | 17.79 MB | Download | |||
Manual - 26-789 ITA | 15.01 MB | Download | |||
RHINO-file - .3dm | .zip | 0.69 MB | Download | ||
X3D-file - .x3d | .zip | 0.14 MB | Download |
BIM - PCD3 processor unit
Tutorial | PCD3.M5360 | BIM - PCD3 processor unit |
CPU base units for 4 plug-in I/O modules - Saia PCD3.M5 series
PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 2 MByte user program, 128 MByte user Flash memory with file system, clock (RTC), USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-232, RS-422/485, RS-485 for Profi-S-Net/S-Bus, data protection 1-3 years
PDS - xlsx | 0.31 MB | Download | |||
Revit-file - .rfa - Revision: - | .zip | 0.74 MB | Download | ||
CREO-export - .sat | .zip | 0.24 MB | Download | ||
STEP-file - .step | .zip | 0.59 MB | Download | ||
STP-file - .stp | .zip | 0.26 MB | Download | ||
DXG-file - .dxf | .zip | 0.20 MB | Download | ||
IFC-file - .ifc | .zip | 0.51 MB | Download | ||
IGES-file - .iges | .zip | 0.27 MB | Download | ||
RHINO-file - .3dm | .zip | 0.70 MB | Download | ||
DS - 31-667 ENG | 0.24 MB | Download | |||
DS - 31-667 FRA | 0.25 MB | Download | |||
DS - 31-667 GER | 0.25 MB | Download | |||
DS - 31-667 ITA | 0.25 MB | Download | |||
Manual - 26-789 ENG | 16.08 MB | Download | |||
Manual - 26-789 FRA | 15.39 MB | Download | |||
Manual - 26-789 GER | 17.79 MB | Download | |||
Manual - 26-789 ITA | 15.01 MB | Download | |||
IGS-file - .igs | .zip | 0.27 MB | Download | ||
X3D-file - .x3d | .zip | 0.14 MB | Download |
BIM - PCD3 processor unit
Tutorial | PCD3.M5340 | BIM - PCD3 processor unit |
CPU base units for 4 plug-in I/O modules - Saia PCD3.M5 series
PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 1 MByte user program, backup option with PCD7.R5xx/R610 Flash card, clock (RTC), data protection 1-3 years, USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-232, RS-422/485, RS-485 for Profi-S-Net/S-Bus
PDS - xlsx | 0.31 MB | Download | |||
Revit-file - .rfa - Revision: a | .zip | 0.74 MB | Download | ||
CREO-export - .sat | .zip | 0.24 MB | Download | ||
STEP-file - .step | .zip | 0.59 MB | Download | ||
STP-file - .stp | .zip | 0.26 MB | Download | ||
DXF-file - .dxf | .zip | 0.20 MB | Download | ||
IFC-file - .ifc | .zip | 0.51 MB | Download | ||
IGES-file - .iges | .zip | 0.27 MB | Download | ||
IGS-file - .igs | .zip | 0.27 MB | Download | ||
RHINO-file - .3dm | .zip | 0.16 MB | Download | ||
X3D-file - .x3d | .zip | 0.14 MB | Download | ||
DS - 26-474 ENG | 0.25 MB | Download | |||
DS - 26-474 FRA | 0.25 MB | Download | |||
DS - 26-474 GER | 0.25 MB | Download | |||
DS - 26-474 ITA | 0.25 MB | Download | |||
Manual - 26-789 ENG | 16.08 MB | Download | |||
Manual - 26-789 FRA | 15.39 MB | Download | |||
Manual - 26-789 GER | 15.71 MB | Download | |||
Manual - 26-600 - ITA | 12.90 MB | Download |
CPU base units for 4 plug-in I/O modules - Saia PCD3.M3 series
BIM - PCD3 processor unit
Tutorial | PCD3.M3360 | BIM - PCD3 processor unit |
CPU base units for 4 plug-in I/O modules - Saia PCD3.M3 series
PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 512 KByte user program, 128 MByte user Flash memory with file system, clock (RTC), USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-485 for Profi-S-Net or S-Bus
PDS - xlsx | 0.31 MB | Download | |||
Revit-file - .rfa - Revision: - | .zip | 0.86 MB | Download | ||
CREO-export - .sat | .zip | 0.21 MB | Download | ||
STEP-file - .step | .zip | 0.51 MB | Download | ||
STP-file - .stp | .zip | 0.22 MB | Download | ||
DXF-file - .dxf | .zip | 0.13 MB | Download | ||
IFC-file - .ifc | .zip | 0.33 MB | Download | ||
IGES-file - .iges | .zip | 0.22 MB | Download | ||
IGS-file - .igs | .zip | 0.22 MB | Download | ||
RHINO-file - .3dm | .zip | 0.53 MB | Download | ||
X3D-file - .x3d | .zip | 0.09 MB | Download | ||
DS - 31-661 ENG | 0.37 MB | Download | |||
DS - 31-661 FRA | 0.37 MB | Download | |||
DS - 31-661 GER | 0.37 MB | Download | |||
DS - 31-661 ITA | 0.38 MB | Download | |||
Manual - 26-789 ENG | 16.08 MB | Download | |||
Manuel - 26-789 FRA | 15.39 MB | Download | |||
Handbuch - 26-789 GER | 17.79 MB | Download | |||
Manuale - 26-789 ITA | 15.01 MB | Download |
BIM - PCD3 processor unit
Tutorial | PCD3.M3330 | BIM - PCD3 processor unit |
CPU base units for 4 plug-in I/O modules - Saia PCD3.M3 series
PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 512 KByte user program, backup with on-board Flash memory, clock (RTC), USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-485 for Profi-S-Net or S-Bus
PDS - xlsx | 0.31 MB | Download | |||
Revit-file - .rfa - Revision: - | .zip | 0.49 MB | Download | ||
CREO-export - .sat | .zip | 0.21 MB | Download | ||
STEP-file - .step | .zip | 0.52 MB | Download | ||
STP-file - .stp | .zip | 0.22 MB | Download | ||
DXF-file - .dxf | .zip | 0.13 MB | Download | ||
IFC-file - .ifc | .zip | 0.34 MB | Download | ||
IGES-file - .iges | .zip | 0.23 MB | Download | ||
IGS-file - .igs | .zip | 0.23 MB | Download | ||
RHINO-file - .3dm | .zip | 0.54 MB | Download | ||
X3D-file - .x3d | .zip | 0.10 MB | Download | ||
DS - 31-660 ENG | 0.37 MB | Download | |||
DS - 31-660 FRA | 0.37 MB | Download | |||
DS - 31-660 GER | 0.37 MB | Download | |||
DS - 31-660 ITA | 0.39 MB | Download | |||
Manual - 26-789 ENG | 16.08 MB | Download | |||
Manuel - 26-789 FRA | 15.39 MB | Download | |||
Handbuch - 26-789 GER | 17.79 MB | Download | |||
Manuel - 26-789 ITA | 15.01 MB | Download |
BIM - PCD3 processor unit
Tutorial | PCD3.M3230 | BIM - PCD3 processor unit |
CPU base units for 4 plug-in I/O modules - Saia PCD3.M3 series
PDS - xlsx | 0.31 MB | Download | |||
Revit-file - .rfa - Revision: - | .zip | 0.50 MB | Download | ||
CREO-export - .sat | .zip | 0.20 MB | Download | ||
STEP-file - .step | .zip | 0.50 MB | Download | ||
STP-file - .stp | .zip | 0.22 MB | Download | ||
DXF-file - .dxf | .zip | 0.13 MB | Download | ||
IFC-file - .ifc | .zip | 0.32 MB | Download | ||
IGES-file - .iges | .zip | 0.22 MB | Download | ||
IGS-file - .igs | .zip | 0.22 MB | Download | ||
RHINO-file - .3dm | .zip | 0.53 MB | Download | ||
X3D-file - .x3d | .zip | 0.09 MB | Download | ||
Manual - 26-789 ENG | 16.08 MB | Download | |||
Manuel - 26-789 FRA | 15.39 MB | Download | |||
Handbuch - 26-789 GER | 17.79 MB | Download | |||
Manuale - 26-789 ITA | 15.01 MB | Download |
BIM - PCD3 processor unit
Tutorial | PCD3.M3160 | BIM - PCD3 processor unit |
CPU base units for 4 plug-in I/O modules - Saia PCD3.M3 series
PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 512 KByte user program, 128 MByte user Flash memory with file system, clock (RTC), USB port for PG5, up to 64 I/O, 2 interrupt inputs, RS-485 for Profi-S-Net or S-Bus
PDS - xlsx | 0.31 MB | Download | |||
Revit-file - .rfa - Revision: a | .zip | 0.62 MB | Download | ||
CREO-export - .sat | .zip | 0.19 MB | Download | ||
STEP-file - .step | .zip | 0.47 MB | Download | ||
STP-file - .stp | .zip | 0.20 MB | Download | ||
DXF-file - .dxf | .zip | 0.11 MB | Download | ||
IFC-file - .ifc | .zip | 0.28 MB | Download | ||
IGES-file - .iges | .zip | 0.21 MB | Download | ||
IGS-file - .igs | .zip | 0.21 MB | Download | ||
RHINO-file - .3dm | .zip | 0.47 MB | Download | ||
X3D-file - .x3d | .zip | 0.08 MB | Download | ||
DS - 31-666 ENG | 0.36 MB | Download | |||
DS - 31-666 FRA | 0.37 MB | Download | |||
DS - 31-666 GER | 0.37 MB | Download | |||
DS - 31-666 ITA | 0.38 MB | Download | |||
Manual - 26-789 ENG | 16.08 MB | Download | |||
Manuel - 26-789 FRA | 15.39 MB | Download | |||
Handbuch - 26-789 GER | 17.79 MB | Download | |||
Manuale - 26-789 ITA | 15.01 MB | Download |
BIM - PCD3 processor unit
Tutorial | PCD3.M3120 | BIM - PCD3 processor unit |
CPU base units for 4 plug-in I/O modules - Saia PCD3.M3 series
PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 128 KByte user program, backup with on-board Flash memory, clock (RTC), USB port for PG5, up to 64 I/O, 2 interrupt inputs, RS-485 for Profi-S-Net or S-Bus
PDS - xlsx | 0.31 MB | Download | |||
Revit-file - .rfa - Revision: a | .zip | 0.62 MB | Download | ||
CREO-export - .sat | .zip | 0.18 MB | Download | ||
STEP-file - .step | .zip | 0.47 MB | Download | ||
STP-file - .stp | .zip | 0.20 MB | Download | ||
DXF-file - .dxf | .zip | 0.11 MB | Download | ||
IFC-file - .ifc | .zip | 0.28 MB | Download | ||
IGES-file - .iges | .zip | 0.20 MB | Download | ||
IGS-file - .igs | .zip | 0.20 MB | Download | ||
RHINO-file - .3dm | .zip | 0.47 MB | Download | ||
X3D-file - .x3d | .zip | 0.08 MB | Download | ||
DS - 26-447 ENG | 0.38 MB | Download | |||
DS - 26-447 FRA | 0.39 MB | Download | |||
DS - 26-447 GER | 0.39 MB | Download | |||
DS - 26-447 ITA | 0.39 MB | Download | |||
Manual - 26-789 ENG | 16.08 MB | Download | |||
Manuel - 26-789 FRA | 15.39 MB | Download | |||
Handbuch - 26-789 GER | 17.79 MB | Download | |||
Manuale - 26-789 ITA | 15.01 MB | Download |
BIM - PCD3 processor unit
Tutorial | PCD3.M3020 | BIM - PCD3 processor unit |
CPU base units for 4 plug-in I/O modules - Saia PCD3.M3 series
PDS - xlsx | 0.31 MB | Download | |||
Revit-file - .rfa - Revision: a | .zip | 0.62 MB | Download | ||
CREO-export - .sat | .zip | 0.18 MB | Download | ||
STEP-file - .step | .zip | 0.46 MB | Download | ||
STP-file - .stp | .zip | 0.20 MB | Download | ||
DXF-file - .dxf | .zip | 0.11 MB | Download | ||
IFC-file - .ifc | .zip | 0.28 MB | Download | ||
IGES-file - .iges | .zip | 0.20 MB | Download | ||
IGS-file - .igs | .zip | 0.20 MB | Download | ||
RHINO-file - .3dm | .zip | 0.46 MB | Download | ||
X3D-file - .x3d | .zip | 0.08 MB | Download | ||
Manual - 26-789 ENG | 16.08 MB | Download | |||
Manuel - 26-789 FRA | 15.39 MB | Download | |||
Hadnbuch - 26-789 GER | 17.79 MB | Download | |||
Manuale - 26-789 ITA | 15.01 MB | Download |
Extension module holders and cables for PCD3.M3xxx/..M5xxx/..M6xxx
BIM - Extension unit for 4 I/O modules
Tutorial | PCD3.C100 | BIM - Extension unit for 4 I/O modules |
Extension module holder for 4 PCD3 I/O modules
PDS - xlsx | 0.31 MB | Download | |||
Revit-file - .rfa - Revision: a | .zip | 0.73 MB | Download | ||
CREO-export - .sat | .zip | 0.14 MB | Download | ||
STEP-file - .step | .zip | 0.35 MB | Download | ||
STP-file - .stp | .zip | 0.15 MB | Download | ||
DXF-file - .dxf | .zip | 0.19 MB | Download | ||
IFC-file - .ifc | .zip | 0.49 MB | Download | ||
IGES-file - .iges | .zip | 0.16 MB | Download | ||
IGS-file - .igs | .zip | 0.16 MB | Download | ||
DS 31-680 ENG | 0.55 MB | Download | |||
DS 31-680 FRA | 0.55 MB | Download | |||
DS 31-680 GER | 0.55 MB | Download | |||
DS 31-680 ITA | 0.55 MB | Download | |||
Manual 26-789 ENG | 16.08 MB | Download | |||
Manual 26-789 FRA | 15.39 MB | Download | |||
Manual 26-789 GER | 17.79 MB | Download | |||
Manual 26-789 ENG | 15.01 MB | Download | |||
Leaflet 35-011 | 0.31 MB | Download | |||
RHINO-file - .3dm | .zip | 0.49 MB | Download | ||
X3D-file - .x3d | .zip | 0.13 MB | Download |
BIM - Extension unit for 2 I/O modules
Tutorial | PCD3.C110 | BIM - Extension unit for 2 I/O modules |
Extension module holder for 2 I/O modules
PDS - xlsx | 0.31 MB | Download | |||
Revit-file - .rfa - Revision: a | .zip | 0.61 MB | Download | ||
CREO-export - .sat | .zip | 0.10 MB | Download | ||
STEP-file - .step | .zip | 0.23 MB | Download | ||
STP-file - .stp | .zip | 0.10 MB | Download | ||
DXF-file - .dxf | .zip | 0.12 MB | Download | ||
IFC-file - .ifc | .zip | 0.29 MB | Download | ||
IGES-file - .iges | .zip | 0.11 MB | Download | ||
IGS-file - .igs | .zip | 0.11 MB | Download | ||
Manual 26-789 - ENG | 16.08 MB | Download | |||
Manual 26-789 - FRA | 15.39 MB | Download | |||
Manual 26-789 - GER | 17.79 MB | Download | |||
Manual 26-789 - ITA | 15.01 MB | Download | |||
RHINO-file - .3dm | .zip | 0.31 MB | Download | ||
X3D-file - .x3d | .zip | 0.08 MB | Download |
BIM - Extension unit for 4 I/O modules ext. pwr.
Tutorial | PCD3.C200 | BIM - Extension unit for 4 I/O modules ext. pwr. |
Extension module holder for 4 I/O modules with terminal connectors for external 24 VDC power supply
PDS - xlsx | 0.31 MB | Download | |||
Revit-file - .rfa - Revision: - | .zip | 0.73 MB | Download | ||
CREO-export - .sat | .zip | 0.14 MB | Download | ||
STEP-file - .step | .zip | 0.35 MB | Download | ||
STP-file - .stp | .zip | 0.15 MB | Download | ||
DXG-file - .dxf | .zip | 0.20 MB | Download | ||
IFC-file - .ifc | .zip | 0.20 MB | Download | ||
IGES-file - .iges | .zip | 0.17 MB | Download | ||
IGS-file - .igs | .zip | 0.17 MB | Download | ||
RHINO-file - .3dm | .zip | 0.49 MB | Download | ||
X3D-file - .x3d | .zip | 0.13 MB | Download | ||
DS 31-682 ENG | 2.10 MB | Download | |||
DS 31-682 FRA | 2.11 MB | Download | |||
DS 31-682 GER | 2.09 MB | Download | |||
DS 31-682 ITA | 2.10 MB | Download | |||
DS 31-682 SPA | 2.11 MB | Download | |||
Manual 26-789 ENG | 16.08 MB | Download | |||
Manuel 26-789 FRA | 15.39 MB | Download | |||
Handbuch 26-789 GER | 17.79 MB | Download | |||
Manuale 26-789 ITA | 15.01 MB | Download | |||
Leaflet 35-011 - ENG | 0.31 MB | Download |
Extension module holders and cables for Compact Controllers PCD3.M2xxx
BIM - Extension unit for 2 I/O modules
Tutorial | PCD3.C110Z09 | BIM - Extension unit for 2 I/O modules |
Extension module holder for 2 I/O modules for compact controllers Saia PCD3
PDS - xlsx | 0.31 MB | Download | |||
Revit-file - .rfa - Revision: - | .zip | 0.63 MB | Download | ||
CREO-export - .sat | .zip | 0.12 MB | Download | ||
STEP-file - .step | .zip | 0.28 MB | Download | ||
STP-file - .stp | .zip | 0.12 MB | Download | ||
DXF-file - .dxf | .zip | 0.13 MB | Download | ||
IFC-file - .ifc | .zip | 0.33 MB | Download | ||
IGES-file - .iges | .zip | 0.13 MB | Download | ||
IGS-file - .igs | .zip | 0.13 MB | Download | ||
Manual 26-861 - ENG | 3.98 MB | Download | |||
Manual 26-861 - FRA | 4.00 MB | Download | |||
Manual 26-861 - GER | 4.12 MB | Download | |||
Manual 26-862 - ENG | 6.05 MB | Download | |||
Manual 26-862 - FRA | 5.91 MB | Download | |||
Manual 26-862 - GER | 5.95 MB | Download | |||
RHINO-file - .3dm | .zip | 0.36 MB | Download | ||
X3D-file - .x3d | .zip | 0.09 MB | Download |
BIM - Extension unit for 4 I/O modules ext. pwr.
Tutorial | PCD3.C200Z09 | BIM - Extension unit for 4 I/O modules ext. pwr. |
Extension module holder for 4 I/O modules
with terminal connectors for external 24 VDC power supply for compact controllers Saia PCD3
PDS - xlsx | 0.31 MB | Download | |||
Revit-file - .rfa - Revision: - | .zip | 0.72 MB | Download | ||
CREO-export - .sat | .zip | 0.16 MB | Download | ||
STEP-file - .step | .zip | 0.39 MB | Download | ||
STP-file - .stp | .zip | 0.17 MB | Download | ||
DXF-file - .dxf | .zip | 0.20 MB | Download | ||
IFC-file - .ifc | .zip | 0.49 MB | Download | ||
IGES-file - .iges | .zip | 0.18 MB | Download | ||
IGS-file - .igs | .zip | 0.18 MB | Download | ||
RHINO-file - .3dm | .zip | 0.51 MB | Download | ||
X3D-file - .x3d | .zip | 0.13 MB | Download | ||
Manual 26-861 - ENG | 3.98 MB | Download | |||
Manuel 26-861 - FRA | 4.00 MB | Download | |||
Handbuch 26-861 - GER | 4.12 MB | Download | |||
Manual 26-862 - ENG | 5.95 MB | Download | |||
Manuel 26-862 - FRA | 5.91 MB | Download | |||
Handbuch 26-862 - GER | 5.95 MB | Download |
Remote data points Saia PCD® - PCD3.T66x
Remote input/output stations with 4 I/O module slots
BIM - Remote data points
Tutorial | PCD3.T668 | BIM - Remote data points |
Remote input/output stations with 4 I/O module slots
Smart-RIO for Standby processor unit, Ether-S-IO data exchange, programmable,
128 KByte program memory, up to 256 I/O, 2 Interrupts, web server and on-board RS-485 interface
PDS - xlsx | 0.31 MB | Download | |||
Revit-file - .rfa - Revision: - | .zip | 0.35 MB | Download | ||
CREO-export - .sat | .zip | 0.20 MB | Download | ||
STEP-file - .step | .zip | 0.50 MB | Download | ||
STP-file - .stp | .zip | 0.22 MB | Download | ||
DXF-file - .dxf | .zip | 0.16 MB | Download | ||
IFC-file - .ifc | .zip | 0.41 MB | Download | ||
IGES-file - .iges | .zip | 0.23 MB | Download | ||
IGS-file - .igs | .zip | 0.23 MB | Download | ||
DS - PP34-006 ENG | 1.51 MB | Download | |||
DS - PP34-006 FRA | 1.52 MB | Download | |||
DS - PP34-006 GER | 1.54 MB | Download | |||
DS - PP34-006 ITA | 1.52 MB | Download | |||
RHINO-file - .3dm | .zip | 0.55 MB | Download | ||
X3D-file - .x3d | .zip | 0.11 MB | Download | ||
Leaflet - 35-017 | 0.10 MB | Download | |||
Manual: 27-645_ENG03 | 6.04 MB | Download |
BIM - Remote data points
Tutorial | PCD3.T666 | BIM - Remote data points |
Remote input/output stations with 4 I/O module slots
Smart-RIO, Ether-S-IO data exchange, programmable, 128 KByte program memory,
up to 256 I/O, 2 Interrupts, web server and on-board RS-485 interface
PDS - xlsx | 0.31 MB | Download | |||
Revit-file - .rfa - Revision: - | .zip | 0.35 MB | Download | ||
CREO-export - .sat | .zip | 0.19 MB | Download | ||
STP-file - .step | .zip | 0.22 MB | Download | ||
STP-file - .stp | .zip | 0.22 MB | Download | ||
DXF-file - .dxf | .zip | 0.16 MB | Download | ||
IFC-file - .ifc | .zip | 0.41 MB | Download | ||
IGES-file - .iges | .zip | 0.22 MB | Download | ||
IGS-file - .igs | .zip | 0.22 MB | Download | ||
Manual - 26-892 ENG | 6.83 MB | Download | |||
Manual - 26-892 FRA | 6.88 MB | Download | |||
Manual - 26-892 GER | 6.83 MB | Download | |||
Manual - 26-892 ITA | 6.87 MB | Download | |||
RHINO-file - .3dm | .zip | 0.54 MB | Download | ||
X3D-file - .x3d | .zip | 0.10 MB | Download | ||
Leaflet - 35-017 | 0.10 MB | Download |
BIM - Remote data points
Tutorial | PCD3.T665 | BIM - Remote data points |
Remote input/output stations with 4 I/O module slots
Smart-RIO, Ether-S-IO data exchange, programmable, 32 KByte program memory,
up to 256 I/O, 2 Interrupts, web server
PDS - xlsx | 0.31 MB | Download | |||
Revit-file - .rfa - Revision: - | .zip | 0.63 MB | Download | ||
CREO-export - .sat | .zip | 0.19 MB | Download | ||
STEP-file - .step | .zip | 0.49 MB | Download | ||
STP-file - .stp | .zip | 0.22 MB | Download | ||
DXF-file - .dxf | .zip | 0.02 MB | Download | ||
IFC-file - .ifc | .zip | 0.40 MB | Download | ||
IGES-file - .iges | .zip | 0.22 MB | Download | ||
IGS-file - .igs | .zip | 0.22 MB | Download | ||
Manual - 26-892 ENG | 6.83 MB | Download | |||
Manual - 26-892 FRA | 6.88 MB | Download | |||
Manual - 26-892 GER | 6.83 MB | Download | |||
Manual - 26-892 ITA | 6.87 MB | Download | |||
RHINO-file - .3dm | .zip | 0.54 MB | Download | ||
X3D-file - .x3d | .zip | 0.11 MB | Download | ||
Leaflet - 35-017 | 0.10 MB | Download |
BIM - Remote data points
Tutorial | PCD3.T660 | BIM - Remote data points |
Remote input/output stations with 4 I/O module slots
RIO, Ether-S-Bus data transfer, not programmable
Revit-file - .rfa - Revision: - | .zip | 0.63 MB | Download | ||
CREO-export - .sat | .zip | 0.19 MB | Download | ||
STEP-file - .step | .zip | 0.49 MB | Download | ||
STP-file - .stp | .zip | 0.21 MB | Download | ||
DXF-file - .dxf | .zip | 0.16 MB | Download | ||
IFC-file - .ifc | .zip | 0.40 MB | Download | ||
IGES-file - .iges | .zip | 0.22 MB | Download | ||
IGS-file - .igs | .zip | 0.22 MB | Download | ||
Manual - 26-892 ENG | 6.83 MB | Download | |||
Manual - 26-892 FRA | 6.88 MB | Download | |||
Manual - 26-892 GER | 6.83 MB | Download | |||
Manual - 26-892 ITA | 6.87 MB | Download | |||
RHINO-file - .3dm | .zip | 0.54 MB | Download | ||
X3D-file - .x3d | .zip | 0.11 MB | Download | ||
Leaflet - 35-017 | 0.10 MB | Download |
Input/output modules for Saia PCD3 controllers
Input/output modules for Saia PCD3 controllers
BIM - Digital output modules 4 relays
Tutorial | PCD3.A200 | BIM - Digital output modules 4 relays |
Input/output modules for Saia PCD3 controllers
Digital output module, 4 relays, 250 VAC/2 A,
'make' contact, contact protection
(connector type A included)
Revit-file - .rfa - Revision: - | .zip | 0.51 MB | Download | ||
CREO-export - .sat | .zip | 0.04 MB | Download | ||
STEP-file - .step | .zip | 0.11 MB | Download | ||
STP-file - .stp | .zip | 0.05 MB | Download | ||
DXF-file - .dxf | .zip | 0.01 MB | Download | ||
IFC-file - .ifc | .zip | 0.03 MB | Download | ||
IGES-file - .iges | .zip | 0.05 MB | Download | ||
IGS-file - .igs | .zip | 0.05 MB | Download | ||
RHINO-file - .3dm | .zip | 0.08 MB | Download | ||
X3D-file - .x3d | .zip | 0.01 MB | Download | ||
DS - 31-600 - ENG | 0.55 MB | Download | |||
DS - 31-600 - FRA | 0.56 MB | Download | |||
DS - 31-600 - GER | 0.56 MB | Download | |||
DS - 31-600 - ITA | 0.55 MB | Download | |||
DS - 31-600 - SPA | 0.55 MB | Download | |||
Manual - 26-600 - ENG | 13.27 MB | Download | |||
Manual - 26-600 - FRA | 16.62 MB | Download | |||
Manual - 26-600 - GER | 15.71 MB | Download | |||
Manual - 26-600 - ITA | 12.90 MB | Download |
BIM - Digital output modules 4 relays
Tutorial | PCD3.A210 | BIM - Digital output modules 4 relays |
Input/output modules for Saia PCD3 controllers
Digital output module, 4 relays, 250 VAC/2 A,
'break' contact, contact protection
(connector type A included)
Revit-file - .rfa - Revision: a | .zip | 0.50 MB | Download | ||
CREO-export - .sat | .zip | 0.04 MB | Download | ||
STEP-file - .step | .zip | 0.11 MB | Download | ||
Step-file - .stp | .zip | 0.11 MB | Download | ||
DXG-file - .dxf | .zip | 0.01 MB | Download | ||
IFC-file - .ifc | .zip | 0.03 MB | Download | ||
IGES-file - .iges | .zip | 0.05 MB | Download | ||
RHINO-file - .3dm | .zip | 0.08 MB | Download | ||
DS - 31-601 - ENG | 0.30 MB | Download | |||
DS - 31-601 - FRA | 0.31 MB | Download | |||
DS - 31-601 - GER | 0.31 MB | Download | |||
DS - 31-601 - ITA | 0.31 MB | Download | |||
DS - 31-601 - SPA | 0.26 MB | Download |
BIM - Digital output modules 2 x 3 relays
Tutorial | PCD3.A220 | BIM - Digital output modules 2 x 3 relays |
Input/output modules for Saia PCD3 controllers
Digital output module, 2 x 3 relays, 250 VAC/2 A
'make' contact, without contact protection
(connector type A included)
Revit-file - .rfa - Revision: - | .zip | 0.51 MB | Download | ||
CREO-export - .sat | .zip | 0.04 MB | Download | ||
STEP-file - .step | .zip | 0.11 MB | Download | ||
STP-file - .stp | .zip | 0.11 MB | Download | ||
DXF-file - .dxf | .zip | 0.01 MB | Download | ||
IFC-file - .ifc | .zip | 0.03 MB | Download | ||
IGES-file - .iges | .zip | 0.05 MB | Download | ||
IGS-file - .iges | .zip | 0.05 MB | Download | ||
RHINO-File - .3dm | .zip | 0.08 MB | Download | ||
X3D-File - .x3d | .zip | 0.01 MB | Download | ||
DS - 31-602 - ENG | 0.69 MB | Download | |||
DS - 31-602 - FRA | 0.69 MB | Download | |||
DS - 31-602 - GER | 0.69 MB | Download | |||
DS - 31-602 - ITA | 0.69 MB | Download | |||
DS - 31-602 - SPA | 0.64 MB | Download |
BIM - Digital output modules 8 relays
Tutorial | PCD3.A251 | BIM - Digital output modules 8 relays |
Input/output modules for Saia PCD3 controllers
Digital output module, 8 relays, 48 VAC/2 A
or 50 VDC/2 A with 6 change-over contacts and
2 make-contacts (connector type C included)
Revit-file - .rfa - Revision: - | .zip | 0.53 MB | Download | ||
CREO-export - .sat | .zip | 0.05 MB | Download | ||
STEP-file - .step | .zip | 0.14 MB | Download | ||
STP-file - .stp | .zip | 0.14 MB | Download | ||
DXF-file - .dxf | .zip | 0.04 MB | Download | ||
IFC-file - .ifc | .zip | 0.11 MB | Download | ||
IGES-file - .iges | .zip | 0.07 MB | Download | ||
IGS-file - .igs | .zip | 0.07 MB | Download | ||
RHINO-file - .3dm | .zip | 0.14 MB | Download | ||
X3D-file - .x3d | .zip | 0.03 MB | Download | ||
DS - 31-603 - ENG | 0.78 MB | Download | |||
DS - 31-603 - FRA | 0.79 MB | Download | |||
DS - 31-603 - GER | 0.79 MB | Download | |||
DS - 31-603 - ITA | 0.78 MB | Download | |||
DS - 31-603 - SPA | 0.74 MB | Download | |||
Manual - 27-600 ENG | 13.27 MB | Download | |||
Manuel - 27-600 FRA | 16.62 MB | Download | |||
Handbuch - 27-600 GER | 15.71 MB | Download | |||
Manuale - 27-600 ITA | 12.90 MB | Download |
BIM - Digital output modules
Tutorial | PCD3.A300 | BIM - Digital output modules |
Input/output modules for Saia PCD3 controllers
Digital output module, 6 outputs, transistors,
10...32 VDC/2 A (connector type A included)
Revit-file - .rfa - Revision: - | .zip | 0.50 MB | Download | ||
CREO-export - .sat | .zip | 0.04 MB | Download | ||
Step-file - .step | .zip | 0.11 MB | Download | ||
STP-file - .stp | .zip | 0.05 MB | Download | ||
DXG-file - .dxf | .zip | 0.01 MB | Download | ||
IFC-file - .ifc | .zip | 0.03 MB | Download | ||
IGES-file - .iges | .zip | 0.05 MB | Download | ||
IGS-file - .igs | .zip | 0.05 MB | Download | ||
RHINO-file - .3dm | .zip | 0.08 MB | Download | ||
X3D-file - .x3d | .zip | 0.01 MB | Download | ||
DS - 31-604 - ENG | 0.59 MB | Download | |||
DS - 31-604 - FRA | 0.59 MB | Download | |||
DS - 31-604 - GER | 0.60 MB | Download | |||
DS - 31-604 - ITA | 0.59 MB | Download | |||
DS - 31-604 - SPA | 0.59 MB | Download |
BIM - Digital output modules
Tutorial | PCD3.A400 | BIM - Digital output modules |
Input/output modules for Saia PCD3 controllers
Digital output module, 8 outputs, transistors,
5...32 VDC/0.5 A (connector type A included)
Revit-file - .rfa - Revision: - | .zip | 0.51 MB | Download | ||
CREO-export - .sat | .zip | 0.04 MB | Download | ||
Step-file - .step | .zip | 0.11 MB | Download | ||
Step-file - .stp | .zip | 0.05 MB | Download | ||
DXG-file - .dxf | .zip | 0.01 MB | Download | ||
IFC-file - .ifc | .zip | 0.03 MB | Download | ||
IGES-file - .iges | .zip | 0.05 MB | Download | ||
IGS-file - .igs | .zip | 0.05 MB | Download | ||
RHINO-file - .3dm | .zip | 0.08 MB | Download | ||
X3D-file - .x3d | .zip | 0.01 MB | Download | ||
DS - 31-605 - ENG | 0.66 MB | Download | |||
DS - 31-605 - FRA | 0.60 MB | Download | |||
DS - 31-605 - GER | 0.60 MB | Download | |||
DS - 31-605 - ITA | 0.59 MB | Download | |||
DS - 31-605 - SPA | 0.60 MB | Download | |||
Manual - 27-600 - ENG | 13.27 MB | Download | |||
Manual - 27-600 - FRA | 16.62 MB | Download | |||
Manual - 27-600 - GER | 15.71 MB | Download | |||
Manual - 27-600 - ITA | 12.90 MB | Download |
BIM - Digital output modules PCD3.A410
Tutorial | PCD3.A410 | BIM - Digital output modules PCD3.A410 |
Input/output modules for Saia PCD3 controllers
Digital output module, 8 outputs, transistors,
5...32 VDC/0.5 A, with galvanic isolation
(connector type A included))
Revit-file - .rfa - Revision: - | .zip | 0.33 MB | Download | ||
CREO-export - .sat | .zip | 0.04 MB | Download | ||
Step-file - .step | .zip | 0.11 MB | Download | ||
Step-file - .stp | .zip | 0.11 MB | Download | ||
DXG-file - .dxf | .zip | 0.01 MB | Download | ||
IFC-file - .ifc | .zip | 0.03 MB | Download | ||
IGES-file - .iges | .zip | 0.05 MB | Download | ||
RHINO-file - .3dm | .zip | 0.08 MB | Download | ||
DS - 31-606 - ENG | 0.23 MB | Download | |||
DS - 31-606 - FRA | 0.25 MB | Download | |||
DS - 31-606 - GER | 0.22 MB | Download | |||
DS - 31-606 - ITA | 0.30 MB | Download | |||
DS - 31-606 - SPA | 0.56 MB | Download | |||
Manual - 27-600 - ENG | 13.27 MB | Download | |||
Manual - 27-600 - FRA | 16.62 MB | Download | |||
Manual - 27-600 - GER | 1.70 MB | Download | |||
Manual - 27-600 - ITA | 12.90 MB | Download |
BIM - Digital output modules PCD3.A60
Tutorial | PCD3.A460 | BIM - Digital output modules PCD3.A60 |
Input/output modules for Saia PCD3 controllers
Digital output module, 16 outputs, transistors, 10…32 VDC/0.5 A, ribbon cable connector for PCD2.K2xx
Revit-file - .rfa - Revision: - | .zip | 0.00 MB | Download | ||
CREO-export - .sat | .zip | 0.13 MB | Download | ||
Step-file - .step | .zip | 0.32 MB | Download | ||
Step-file - .stp | .zip | 0.13 MB | Download | ||
DXG-file - .dxf | .zip | 0.04 MB | Download | ||
IFC-file - .ifc | .zip | 0.11 MB | Download | ||
IGES-file - .iges | .zip | 0.15 MB | Download | ||
RHINO-file - .3dm | .zip | 0.28 MB | Download | ||
DS - 31-607 - ENG | 0.30 MB | Download | |||
DS - 31-607 - FRA | 0.33 MB | Download | |||
DS - 31-607 - GER | 0.33 MB | Download | |||
DS - 31-607 - ITA | 0.30 MB | Download | |||
DS - 31-607 - ESP | 0.31 MB | Download | |||
Manual - 27-600 - ENG | 13.27 MB | Download | |||
Manual - 27-600 - FRA | 16.62 MB | Download | |||
Manual - 27-600 - GER | 15.71 MB | Download | |||
Manual - 27-600 - ITA | 12.90 MB | Download |
BIM - Digital output modules PCD3.A465
Tutorial | PCD3.A465 | BIM - Digital output modules PCD3.A465 |
Input/output modules for Saia PCD3 controllers
Digital output module, 16 outputs, transistors,
10…32 VDC/0.5 A (connector type C included)
Revit-file - .rfa - Revision: - | .zip | 0.53 MB | Download | ||
CREO-export - .sat | .zip | 0.05 MB | Download | ||
STEP-file - .step | .zip | 0.14 MB | Download | ||
STP-file - .stp | .zip | 0.14 MB | Download | ||
DXF-file - .dxf | .zip | 0.04 MB | Download | ||
IFC-file - .ifc | .zip | 0.11 MB | Download | ||
IGES-file - .iges | .zip | 0.07 MB | Download | ||
IGS-file - .igs | .zip | 0.07 MB | Download | ||
RHINO-file - .3dm | .zip | 0.14 MB | Download | ||
X3D-file - .x3d | .zip | 0.03 MB | Download | ||
DS - 31-608 - ENG | 0.56 MB | Download | |||
DS - 31-608 - FRA | 0.56 MB | Download | |||
DS - 31-608 - GER | 0.56 MB | Download | |||
DS - 31-608 - ITA | 0.56 MB | Download | |||
DS - 31-608 - SPA | 0.56 MB | Download | |||
Manual - 27-600 ENG | 13.27 MB | Download | |||
Manuel - 27-600 FRA | 16.62 MB | Download | |||
Handbuch - 27-600 GER | 15.71 MB | Download | |||
Manuale - 27-600 ITA | 12.90 MB | Download |
BIM - Combined digital input/output modules
Tutorial | PCD3.B100 | BIM - Combined digital input/output modules |
Input/output modules for Saia PCD3 controllers
Digital input/output module with 8 I/O,
2 inputs, 2 outputs and 4 configurable I/O's
Inputs : 24 VDC, source operation, delay 8 ms
Outputs : breaking capacity 5...32 VDC/0.5 A
(connector type A included)
Revit-file - .rfa - Revision: - | .zip | 0.46 MB | Download | ||
CREO-export - .sat | .zip | 0.04 MB | Download | ||
STEP-file - .step | .zip | 0.11 MB | Download | ||
STP-file - .stp | .zip | 0.11 MB | Download | ||
DXF-file - .dxf | .zip | 0.01 MB | Download | ||
IFC-file - .ifc | .zip | 0.03 MB | Download | ||
IGES-file - .iges | .zip | 0.05 MB | Download | ||
IGS-file - .iges | .zip | 0.05 MB | Download | ||
RHINO-file - .3dm | .zip | 0.08 MB | Download | ||
X3D-file - .x3d | .zip | 0.01 MB | Download | ||
DS - 31-611 - ENG | Download | ||||
DS - 31-611 - FRA | Download | ||||
DS - 31-611 - GER | Download | ||||
DS - 31-611 - ITA | Download | ||||
DS - 31-611 - SPA | Download | ||||
Manual - 27-600 - ENG | 13.27 MB | Download | |||
Manual - 27-600 - FRA | 16.62 MB | Download | |||
Manual - 27-600 - GER | 15.71 MB | Download | |||
Manual - 27-600 - ITA | 12.90 MB | Download |
BIM - Combined digital input/output modules
Tutorial | PCD3.B160 | BIM - Combined digital input/output modules |
Combined digital input/output modules Saia PCD3 controllers
Digital input/output module with 16 I/O,
configurable either as inputs or as outputs in groups of four (4)
Inputs : 24 VDC, source operation, delay 0.2/8 ms
Outputs : breaking capacity 5…30 VDC/0.5 A (2 connectors type K included)
Revit-file - .rfa - Revision: - | .zip | 0.54 MB | Download | ||
CREO-export - .sat | .zip | 0.06 MB | Download | ||
Step-file - .step | .zip | 0.15 MB | Download | ||
STP-file - .stp | .zip | 0.15 MB | Download | ||
DXF-file - .dxf | .zip | 0.04 MB | Download | ||
IFC-file - .ifc | .zip | 0.11 MB | Download | ||
IGES-file - .iges | .zip | 0.07 MB | Download | ||
IGS-file - .igs | .zip | 0.07 MB | Download | ||
RHINO-file - .3dm | .zip | 0.15 MB | Download | ||
X3D-file - .x3d | .zip | 0.03 MB | Download | ||
DS - 31-612 - ENG | 1.25 MB | Download | |||
DS - 31-612 - FRA | 1.26 MB | Download | |||
DS - 31-612 - GER | 1.27 MB | Download | |||
DS - 31-612 - ITA | 1.27 MB | Download | |||
DS - 31-612 - SPA | 1.27 MB | Download | |||
Manual 27-600 - ENG | 13.27 MB | Download | |||
Manual 27-600 - FRA | 16.62 MB | Download | |||
Manual 27-600 - GER | 15.71 MB | Download | |||
Manual 27-600 - ITA | 12.90 MB | Download |
BIM - Empty module housing for unused PCD3 I/O slots
Tutorial | PCD3.E009 | BIM - Empty module housing for unused PCD3 I/O slots |
Input/output modules for Saia PCD3 controllers
Empty module housing for unused PCD3 I/O slots
Revit-file - .rfa - Revision: - | .zip | 0.44 MB | Download | ||
CREO-export - .sat | .zip | 0.02 MB | Download | ||
STEP-file - .step | .zip | 0.04 MB | Download | ||
STP-file - .stp | .zip | 0.04 MB | Download | ||
DXF-file - .dxf | .zip | 0.01 MB | Download | ||
IFC-file - .ifc | .zip | 0.02 MB | Download | ||
IGES-file - .iges | .zip | 0.02 MB | Download | ||
IGS-file - .igs | .zip | 0.02 MB | Download | ||
RHINO-file - .3dm | .zip | 0.04 MB | Download | ||
X3D-file - .x3d | .zip | 0.00 MB | Download | ||
Manual - 27-600 - ENG | 13.27 MB | Download | |||
Manual - 27-600 - FRA | 16.62 MB | Download | |||
Manual - 27-600 - GER | 15.71 MB | Download | |||
Manual - 27-600 - ITA | 12.90 MB | Download |
BIM - Digital input modules
Tutorial | PCD3.E110 | BIM - Digital input modules |
Input/output modules for Saia PCD3 controllers
Digital input module, 8 inputs, 24 VDC,
source and sink operation, 8 ms input delay.
(connector type A included)
Revit-file - .rfa - Revision: - | .zip | 0.33 MB | Download | ||
CREO-export - .sat | .zip | 0.04 MB | Download | ||
Step-file - .step | .zip | 0.11 MB | Download | ||
Step-file - .stp | .zip | 0.11 MB | Download | ||
DXG-file - .dxf | .zip | 0.01 MB | Download | ||
IFC-file - .ifc | .zip | 0.03 MB | Download | ||
IGES-file - .iges | .zip | 0.05 MB | Download | ||
RHINO-file - .2dm | .zip | 0.08 MB | Download | ||
DS - 31-614 - ENG | 0.32 MB | Download | |||
DS - 31-614 - FRA | 0.33 MB | Download | |||
DS - 31-614 - GER | 0.33 MB | Download | |||
DS - 31-614 - ITA | 0.33 MB | Download | |||
DS - 31-614 - SPA | 0.72 MB | Download | |||
Manual - 27-600 - ENG | 13.27 MB | Download | |||
Manual - 27-600 - FRA | 16.62 MB | Download | |||
Manual - 27-600 - GER | 15.71 MB | Download | |||
Manual - 27-600 - ITA | 12.90 MB | Download |
BIM - Digital input modules
Tutorial | PCD3.E111 | BIM - Digital input modules |
Input/output modules for Saia PCD3 controllers
Digital input module, 8 inputs, 24 VDC,
source and sink operation, 0.2 ms input delay
(connector type A included)
Revit-file - .rfa - Revision: - | .zip | 0.44 MB | Download | ||
CREO-export - .sat | .zip | 0.04 MB | Download | ||
Step-file - .step | .zip | 0.11 MB | Download | ||
Step-file - .stp | .zip | 0.11 MB | Download | ||
DXG-file - .dxf | .zip | 0.01 MB | Download | ||
IFC-file - .ifc | .zip | 0.03 MB | Download | ||
IGES-file - .iges | .zip | 0.05 MB | Download | ||
IGS-file - .igs | .zip | 0.05 MB | Download | ||
RHINO-file - .3dm | .zip | 0.08 MB | Download | ||
X3D-file - .x3D | .zip | 0.01 MB | Download | ||
DS - 31-614 - ENG | 0.71 MB | Download | |||
DS - 31-614 - FRA | 0.72 MB | Download | |||
DS - 31-614 - GER | 0.74 MB | Download | |||
DS - 31-614 - ITA | 0.72 MB | Download | |||
DS - 31-614 - SPA | 0.72 MB | Download | |||
Manual 27-600 - ENG | 13.27 MB | Download | |||
Manual 27-600 - FER | 16.62 MB | Download | |||
Manual 27-600 - GER | 15.71 MB | Download | |||
Manual 27-600 - ITA | 12.90 MB | Download |
BIM - Digital input modules PCD3.E160
Tutorial | PCD3.E160 | BIM - Digital input modules PCD3.E160 |
Input/output modules for Saia PCD3 controllers
Digital input module, 16 inputs, 24 VDC, source and sink operation, 8 ms input delay, ribbon cable connector for PCD2.K2xx
Revit-file - .rfa - Revision: a | .zip | 0.94 MB | Download | ||
CREO-export - .sat | .zip | 0.13 MB | Download | ||
Step-file - .step | .zip | 0.32 MB | Download | ||
Step-file - .stp | .zip | 0.13 MB | Download | ||
DXG-file - .dxf | .zip | 0.04 MB | Download | ||
IFC-file - .ifc | .zip | 0.11 MB | Download | ||
IGES-file - .iges | .zip | 0.15 MB | Download | ||
RHINO-file - .3dm | .zip | 0.28 MB | Download | ||
DS - 31-618 - ENG | 0.42 MB | Download | |||
DS - 31-618 - FRA | 0.42 MB | Download | |||
DS - 31-618 - GER | 0.43 MB | Download | |||
DS - 31-618 - ITA | 0.42 MB | Download | |||
DS - 31-618 - ESP | 0.37 MB | Download | |||
Manual - 27-600 - ENG | 13.27 MB | Download | |||
Manual - 27-600 - FRA | 16.62 MB | Download | |||
Manual - 27-600 - GER | 15.71 MB | Download | |||
Manual - 27-600 - ITA | 12.90 MB | Download |
BIM - Digital input modules PCD3.E165
Tutorial | PCD3.E165 | BIM - Digital input modules PCD3.E165 |
Input/output modules for Saia PCD3 controllers
Digital input module, 16 inputs, 24 VDC,
source and sink operation, 8 ms input delay,
(connector type C included)
Revit-file - .rfa - Revision: - | .zip | 0.53 MB | Download | ||
CREO-export - .sat | .zip | 0.05 MB | Download | ||
STEP-file - .step | .zip | 0.14 MB | Download | ||
STP-file - .stp | .zip | 0.14 MB | Download | ||
DXF-file - .dxf | .zip | 0.04 MB | Download | ||
IFC-file - .ifc | .zip | 0.11 MB | Download | ||
IGES-file - .iges | .zip | 0.07 MB | Download | ||
IGS-file - .igs | .zip | 0.07 MB | Download | ||
RHINO-file - .3dm | .zip | 0.14 MB | Download | ||
X3D-file - .x3d | .zip | 0.03 MB | Download | ||
DS - 31-620 - ENG | 0.73 MB | Download | |||
DS - 31-620 - FRA | 0.75 MB | Download | |||
DS - 31-620 - GER | 0.76 MB | Download | |||
DS - 31-620 - ITA | 0.75 MB | Download | |||
DS - 31-620 - SPA | 0.75 MB | Download | |||
Manual - 27-600 ENG | 13.27 MB | Download | |||
Manuel - 27-600 FRA | 16.62 MB | Download | |||
Handbuch - 27-600 GER | 15.71 MB | Download | |||
Manuale - 27-600 ITA | 12.90 MB | Download |
BIM - Digital input modules PCD3.E166
Tutorial | PCD3.E166 | BIM - Digital input modules PCD3.E166 |
Input/output modules for Saia PCD3 controllers
Digital input module, 16 inputs, 24 VDC,
source and sink operation, 0.2 ms input delay,
(connector type C included)
Revit-file - .rfa - Revision: - | .zip | 0.53 MB | Download | ||
CREO-export - .sat | .zip | 0.05 MB | Download | ||
STEP-file - .step | .zip | 0.14 MB | Download | ||
STP-file - .stp | .zip | 0.14 MB | Download | ||
DXF-file - .dxf | .zip | 0.04 MB | Download | ||
IFC-file - .ifc | .zip | 0.11 MB | Download | ||
IGES-file - .iges | .zip | 0.07 MB | Download | ||
IGS-file - .igs | .zip | 0.07 MB | Download | ||
RHINO-file - .3dm | .zip | 0.14 MB | Download | ||
X3D-file - .x3d | .zip | 0.03 MB | Download | ||
DS - 31-621 - ENG | 0.73 MB | Download | |||
DS - 31-621 - FRA | 0.75 MB | Download | |||
DS - 31-621 - GER | 0.76 MB | Download | |||
DS - 31-621 - ITA | 0.75 MB | Download | |||
DS - 31-621 - SPA | 0.75 MB | Download | |||
Manual - 27-600 ENG | 13.27 MB | Download | |||
Manuel - 27-600 FRA | 16.62 MB | Download | |||
Handbuch - 27-600 GER | 15.71 MB | Download | |||
Manuale - 27-600 ITA | 12.90 MB | Download |
BIM - Digital input modules
Tutorial | PCD3.E500 | BIM - Digital input modules |
Input/output modules for Saia PCD3 controllers
Digital input modules with galvanic isolation
Digital input module, 6 inputs, 110...240 VAC, with galvanic isolation, source operation
Revit-file - .rfa - Revision: - | .zip | 0.57 MB | Download | ||
CREO-export - .sat | .zip | 0.04 MB | Download | ||
Step-file - .step | .zip | 0.11 MB | Download | ||
Stp-file - .stp | .zip | 0.11 MB | Download | ||
DXG-file - .dxf | .zip | 0.01 MB | Download | ||
IFC-file - .ifc | .zip | 0.03 MB | Download | ||
IGES-file - .iges | .zip | 0.05 MB | Download | ||
IGS-file - .igs | .zip | 0.05 MB | Download | ||
RHINO-file - .3dm | .zip | 0.08 MB | Download | ||
X3D-file - .x3D | .zip | 0.01 MB | Download | ||
DS - 31-622 - ENG | 0.77 MB | Download | |||
DS - 31-622 - FRA | 0.78 MB | Download | |||
DS - 31-622 - GER | 0.80 MB | Download | |||
DS - 31-622 - ITA | 0.77 MB | Download | |||
DS - 31-622 - SPA | 0.77 MB | Download | |||
Manual 27-600 - ENG | 13.27 MB | Download | |||
Manual 27-600 - FER | 16.62 MB | Download | |||
Manual 27-600 - GER | 15.71 MB | Download | |||
Manual 27-600 - ITA | 12.90 MB | Download |
BIM - Digital input modules for Saia PCD3 controllers
Tutorial | PCD3.E610 | BIM - Digital input modules for Saia PCD3 controllers |
Input/output modules for Saia PCD3 controllers
Digital input modules with galvanic isolation
Digital input module, 8 inputs, 24 VDC, with galvanic isolation, source and sink operation, 10 ms input delay (connector type A included)
PDS - xlsx | Download | ||||
Revit-file - .rfa - Revision: - | Download | ||||
CREO-export - .sat | .zip | 0.04 MB | Download | ||
Step-file - .step | .zip | 0.11 MB | Download | ||
Step-file - .stp | .zip | 0.11 MB | Download | ||
DXG-file - .dxf | .zip | 0.01 MB | Download | ||
IFC-file - .ifc | .zip | 0.03 MB | Download | ||
IGES-file - .iges | .zip | 0.05 MB | Download | ||
RHINO-file - .3DM | .zip | 0.08 MB | Download | ||
DS - 31-623 - ENG | 0.78 MB | Download | |||
DS - 31-623 - FRA | 0.80 MB | Download | |||
DS - 31-623 - GER | 0.82 MB | Download | |||
DS - 31-623 - ITA | 0.79 MB | Download | |||
DS - 31-623 - SPA | 0.80 MB | Download | |||
Manual 26-789 - ENG | 16.08 MB | Download | |||
Manual 26-789 - FRA | 15.39 MB | Download | |||
Manual 26-789 - GER | 17.79 MB | Download | |||
Manual 26-789 - ITA | 15.01 MB | Download |
BIM - Digital input modules for Saia PCD3 controllers
Tutorial | PCD3.E613 | BIM - Digital input modules for Saia PCD3 controllers |
Input/output modules for Saia PCD3 controllers
Digital input modules with galvanic isolation
Digital input module, 6 inputs, 110...240 VAC, with galvanic isolation, source operation
Revit-file - .rfa - Revision: - | .zip | 0.53 MB | Download | ||
CREO-export - .sat | .zip | 0.04 MB | Download | ||
Step-file - .step | .zip | 0.11 MB | Download | ||
Stp-file - .stp | .zip | 0.11 MB | Download | ||
DXG-file - .dxf | .zip | 0.01 MB | Download | ||
IFC-file - .ifc | .zip | 0.03 MB | Download | ||
IGES-file - .iges | .zip | 0.05 MB | Download | ||
IGS-file - .igs | .zip | 0.05 MB | Download | ||
RHINO-file - .3dm | .zip | 0.08 MB | Download | ||
X3D-file - .x3D | .zip | 0.01 MB | Download | ||
DS - 31-625 - ENG | 0.82 MB | Download | |||
DS - 31-625 - FRA |