protocol for PCD2/3.F2xx(x) e.g. used by the M-Bus library 2.6.100 and later SF library 23: Energy Manager library SF library 25: LON FT library SF library 27: ELine library for ELine modules
serial number of the S-Bus, M-Bus or Modbus one-phase and three-phase energy meter is printed on the front of the energy meter and it's also possible to read out the serial number over the communication [...] three-phase energy meters with S-Bus, M-Bus or Modbus communication. Note also that the format of the serial number has changed for the S-Bus and Modbus (is now ASCII) and due of this it's necessary to [...] Comm. interface Prod.date =1322 S-Bus Register 13 12, 13 Modbus Register 16, 17 16, 17, 18 M-Bus Byte 8, 9, 10, 11 8, 9, 10, 11
serial number of the S-Bus, M-Bus or Modbus one-phase and three-phase energy meter is printed on the front of the energy meter and it's also possible to read out the serial number over the communication [...] three-phase energy meters with S-Bus, M-Bus or Modbus communication. Note also that the format of the serial number has changed for the S-Bus and Modbus (is now ASCII) and due of this it's necessary to [...] Comm. interface Prod.date =1322 S-Bus Register 13 12, 13 Modbus Register 16, 17 16, 17, 18 M-Bus Byte 8, 9, 10, 11 8, 9, 10, 11
protocol for PCD2/3.F2xx(x) e.g. used by the M-Bus library 2.6.100 and later The single function codes (second line of the CSF call, "0" in the screenshot above) of the relevant libraries can be found
protocol for PCD2/3.F2xx(x) e.g. used by the M-Bus library 2.6.100 and later The single function codes (second line of the CSF call, "0" in the screenshot above) of the relevant libraries can be found
Principally, there's no limitations set by the driver itself ...
When connecting M-Bus devices to a PCD there are some points to be considered already during planning and commissioning. This FAQ refers to a list of points to check when realizing and trouble-shooting M-Bus communication.
The M-Bus communication between the "Hydrometer M-Bus Receiver 868" (alternatively called "MB-Receiver") and the PCD2.F2710 has been analyzed and it was found that the device does not conform to the M-Bus specification (SN EN 13757-2). Therefore it can not be used together with the PCD2/3.F27x(0).
As described in FAQ 101479 the version 2.6.xxx of the Engiby libraries is required for PG5 2.0.150 (PG5 2.0 SP1). This FAQ contains the link to download the libraries (in order to have a fast solution
Product Category Communication protocols M-Bus General [...] M-Bus on Saia PCD® PCD2.F27x0 and PCD3.F27x Introduction A PCD1.M2, PCD2.M5 or PCD3 can act as M-Bus Master using the according connection interface module PCD3.F27x or PCD2.F27x0. Module overview There exist 4 different M-Bus module types to be plugged into PCD I