Communication interfaces for specific protocols for PCD3.M1xxx/..M2xxx M-Bus master interface module for up to 20 M-Bus slave addresses freely distributable on 2 M-Bus interfaces - to be placed in I/O slots 0..3
Communication interfaces for specific protocols for PCD3.M1xxx/..M2xxx Serial interface module with 2 M-Bus interfaces for up to 120 M-Bus slavess - to be placed in I/O slots 0..3
Three-phase energy meters with integral M-Bus interface for direct measurement, 3x 230/400 VAC - 50 Hz Three-phase two-way energy meter with LCD display M-Bus interface, Imax = 65 A display of active power, voltage and current according to MID directive
Three-phase energy meters with integral M-Bus interface for direct measurement, 3x 230/400 VAC - 50 Hz Three-phase energy meter with LCD display M-Bus interface, Imax = 65 A, 2 tariffs display of active power, voltage and current according to MID directive
Three-phase energy meters with integral M-Bus interface for current transformer (CT) measurement, 3x 230/400 VAC - 50 Hz Three-phase energy meter with LCD display M-Bus interface, 5…1'500 A, 1 tariff display of active power, voltage and current according to MID directive
Single-phase energy meters with integral M-Bus interface for direct measurement, 230 VAC - 50 Hz Single-phase energy meter with LCD display M-Bus interface, Imax = 32 A, 1 tariff display of active power, voltage and current according to MID directive
3-phase energy meter ALE3 with M-Bus (bidirectional) Order number MID version: ALE3B5FM00C3A00 Sealing cap: 4 104 7485 0 Specifications - 3-phase energy meter, 3 × 230 / 400 VAC 50 Hz - Direct metering to 65 A in both directions of current - Display of the active power, voltage and current per phase - Display of the total active power - M-Bus interface used to query data - Idle power per phase or total available via the interface - Up to 254 energy meters can be connected to a single M-Bus interface. - 7-digit LCD display for energy supply and feeding back - Can be sealed and is provided
HONEYWELL branded energy meter Main Features: - 3-phase energy meter, 3 × 230/400VAC 50Hz - Direct measuring up to 65A - Display of active power, voltage and current for every phase - Display of active power for all phases - M-Bus interface to retrieve the data - Reactive power per phase or total, available via M-Bus interface - Up to 250 meters can be addressed trough primary addresses - 7-digit display - Can be sealed with sealing cap (optional) - Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
HONEYWELL branded energy meter Main Features: - 3-phase energy meter, 3 × 230/400VAC50Hz - Measurement through a current transformer up to 1500A - Display of active power, voltage and current for every phase - Display of active power for all phases - M-Bus interface to retrieve the data - Reactive power per phase or total, available via M-Bus interface - Up to 250 meters can be addressed trough primary addresses - 7-digit display - Can be sealed with sealing cap (optional) - Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
HONEYWELL branded energy meter Main features: - Single-phase energy meter, 230 VAC 50 Hz - Direct measurement up to 32 A - Display of active power, voltage and current - M-Bus interface to query the data - Reactive power available through interface - Up to 250 meter can be connected to the M-Bus interface - 7-digit display - Lead seal possible with cap as accessory - Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21