. Why do I get the error "Missing value" when reading some M-Bus devices? (FAQ #101762) When reading values from some specific M-Bus devices with the M-Bus modules PCD2/3.F27xx, the M-Bus driver may show the error "Missing value" even though all values are correctly returned by the device. Symptom When using the M-Bus modules PCD2/3.F27xx (with the framing protocol), the M-Bus driver may display the error "Missing value" even though all values are correctly returned. The problem concerns only few devices
Communication drivers (M-Bus, Modbus...), FBoxes, Data Logging with remote communication
. 1-ph. M-Bus Interf. 3-ph. M-Bus Interf
HONEYWELL branded energy meter Main Features: - 3-phase energy meter, 3 × 230/400VAC50Hz - Measurement through a current transformer up to 1500A - Display of active power, voltage and current for every phase - Display of active power for all phases - M-Bus interface to retrieve the data - Reactive power per phase or total, available via M-Bus interface - Up to 250 meters can be addressed trough primary addresses - 7-digit display - Can be sealed with sealing cap (optional) - Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
HONEYWELL branded energy meter Main Features: - 3-phase energy meter, 3 × 230/400VAC 50Hz - Direct measuring up to 65A - Display of active power, voltage and current for every phase - Display of active power for all phases - M-Bus interface to retrieve the data - Reactive power per phase or total, available via M-Bus interface - Up to 250 meters can be addressed trough primary addresses - 7-digit display - Can be sealed with sealing cap (optional) - Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
HONEYWELL branded energy meter Main Features: - 3-phase energy meter, 3 × 230/400VAC 50Hz - Direct measuring up to 65A - Display of active power, voltage and current for every phase - Display of active power for all phases - M-Bus interface to retrieve the data - Reactive power per phase or total, available via M-Bus interface - Up to 250 meters can be addressed trough primary addresses - 7-digit display - Can be sealed with sealing cap (optional) - Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
HONEYWELL branded energy meter Main features: - Single-phase energy meter, 230 VAC 50 Hz - Direct measurement up to 32 A - Display of active power, voltage and current - M-Bus interface to query the data - Reactive power available through interface - Up to 250 meter can be connected to the M-Bus interface - 7-digit display - Lead seal possible with cap as accessory - Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
power for every phase and for the three phases. SBC S-Bus M-Bus Modbus S0-interface Saia PCD S0 pulse
protocol for PCD2/3.F2xx(x) e.g. used by the M-Bus library 2.6.100 and later The single function codes (second line of the CSF call, "0" in the screenshot above) of the relevant libraries can be found
The serial number of the S-Bus, M-Bus or Modbus one-phase and three-phase energy meter is printed on the front of the energy meter and it's also possible to read out the serial number over the communication interface. Until June 2013 the two serial numbers were different one from the other, but each one was unique.