are connected to PCD3.Mxxx or PCD2.M480 PLC's over Profi S-Bus, the terminal loses the communication after some time and get even frozen. This problem is corrected in the new boot, FW and driver. The PCD8.D81 V 5.09 is needed , the attached files have to be copied in it (see procedure below). It is also necessary to update the PCD3.Mxxx and PCD2.M480 FW with the version PCD3.Mxxx_023.blk / PCD2.M [...] OS do not allow the access to COM-ports in the way which is used for DOS. Use an operating system which is based on DOS (DOS, WIN 3.11, Windows 95 or Windows 98) instead. PCD7.D8 is a
Communication / BACnet On a PCD3.M6860 it’s possible to [...] 1 or ETH2 of the PCD3.M6860. In PG5 it’s possible to activate at the same time BACnet on ETH1 and ETH2 but we strongly recommend to use/activate BACnet only on one of the two Ethernet ports to avoid a bad behavior on BACnet. The activation and selection of the used Ethernet port for BACnet communication on the PCD3.M6860 is done in PG5 2.2 or PG5 2.3 in the device configurator
itselfs influences the measurement it has been stated that the precisision is not according to the manual of this PCD7.D290 display (26/841 version 4). The chapters 4.2.3 (Temperature sensor) and 4.2.4 (R.H. sensor) will be adapted accordingly in the next release. 4.2.3 Temperature sensor Temperature sensor used in PCD7.D290 is active and supplies as output a voltage of 10.0 mV/°C; this [...] Product Index Archive PCD7 Dxxx: HMI D290: Text terminal General
itselfs influences the measurement it has been stated that the precisision is not according to the manual of this PCD7.D290 display (26/841 version 4). The chapters 4.2.3 (Temperature sensor) and 4.2.4 (R.H. sensor) will be adapted accordingly in the next release. 4.2.3 Temperature sensor Temperature sensor used in PCD7.D290 is active and supplies as output a voltage of 10.0 mV/°C; this [...] Product Category HMI Text Terminal PCD7.D290 General
.06.2019 #102031 - On a PCD3.M6860 it’s possible to use BACnet on the Ethernet port ETH1 and/or on ETH [...] -Bus? 21.12.2018 #102028 - Why do the 0 to 10 V analog outputs of the PCD3.W800 cards 'freeze' to a random value during operation and cannot be controlled by the user [...] )? 19.01.2018 #102014 - Why do the output of the PCD2/3.W6x5 not deliver stable signals
.06.2019 #102031 - On a PCD3.M6860 it’s possible to use BACnet on the Ethernet port ETH1 and/or on ETH [...] -Bus? 21.12.2018 #102028 - Why do the 0 to 10 V analog outputs of the PCD3.W800 cards 'freeze' to a random value during operation and cannot be controlled by the user [...] )? 19.01.2018 #102014 - Why do the output of the PCD2/3.W6x5 not deliver stable signals
. HMI Editor and PCD3.M_ or PCD2.M480: Wrong characters are display instead of value with Format #####! (FAQ #100360) When an element is configured as Integer with the format ##### (without dot) the value of the register is wrongly displayed on the terminal. This is a FW bug in the actual version of the PCD3.M_ and PCD2.M480. This problem occurs with all FW version up to: PCD3.M_ #13 (that means also 010, #11, #12) PCD2.M480 #23 (that means also 020, #21, #22) Solution Please
. HMI Editor and PCD3.M_ or PCD2.M480: Wrong characters are display instead of value with Format #####! (FAQ #100360) When an element is configured as Integer with the format ##### (without dot) the value of the register is wrongly displayed on the terminal. This is a FW bug in the actual version of the PCD3.M_ and PCD2.M480. This problem occurs with all FW version up to: PCD3.M_ #13 (that means also 010, #11, #12) PCD2.M480 #23 (that means also 020, #21, #22) Solution Please
some protective measures. Information about protective measures can be found on the support hp If you need a PCD with cyber security levels SL3+ and based on ANSI ISA 62443 then checkout our PCD3.M6893 (QronoX PCD), this PCD was developed for cybersecure applications. Information's can be found here . [...] with header line N4.3 On the Niagara article, for the Saia-PCD Supervisor version 1.1, check the column with header line N
Product Category Remote I/O PCD7.Lxxx S-Bus RIO L3xx: Analogue input RIO [...] PCD7.L3xx S-Bus remote I/O's Documentation [...] speed of the PCD7-L60x-1 Example: If the register has the value: ‘30’ then the maximum speed would be 3 and the minimum speed 0 ‘22’ then the maximum speed would be 2 and the minimum speed 2 -> the