. Web-Editor functions PCD3 Mxxx0 PCD2 M5xx0 PCD2 M480 PCD1.M135 PCD2.M1x0 PCS1 PCD3 Mxxx7 PCD2 M5xx7 PCD2.M487 PCD2.M1x7 Web Server 2 [...] PG5 1.4.300 the S-Web Editor together with an example, the required FBoxes and firmware versions for PCD2.M5xx0 and PCD3.Mxxx0 can be downloaded from the support site from section Software --> PG5 --> [...] supporting various features. Web-Editor functions PCD3.Mxx0 PCD2.M480 PCD2.M170 PCD2.M150 PCD1.M135 PCS1.Cxxx PCD3.Mxx7 Trending
are connected to PCD3.Mxxx or PCD2.M480 PLC's over Profi S-Bus, the terminal loses the communication after some time and get even frozen. This problem is corrected in the new boot, FW and driver. The PCD8.D81 V 5.09 is needed , the attached files have to be copied in it (see procedure below). It is also necessary to update the PCD3.Mxxx and PCD2.M480 FW with the version PCD3.Mxxx_023.blk / PCD2.M [...] OS do not allow the access to COM-ports in the way which is used for DOS. Use an operating system which is based on DOS (DOS, WIN 3.11, Windows 95 or Windows 98) instead. PCD7.D8 is a
connect electrical sensors. The module is freely programmable and can also be used as a “standalone” DALI small controller. Saia PCD2/3.F26x A PCD1.M2, PCD2.M5, PCD3.M as well as a PCD3 [...] for the PCD1.M2 and PCD2.M5 PCD2.F2610 64 ballasts Modules for PCD3.Mxxx0 and PCD3.T666 PCD3.F261 64 ballasts Documentation FBoxes for working [...] .F221 Workaround to use the RS-232 S-Bus communication over converters: For the PCD3: Instead of using a PCD3.F221, use the PCD3.F121. For PCD1.M2 or PCD2.M5: Instead of using a PCD2.F2xx0, use the PCD
The diagnostic flag TBSY of the "Character Mode" (used for sending characters over a serial line) is not handled the same way on a PCD3 compared to "older" systems like e.g. PCD2.M170.
Documents Documents for ControlEdge PCD Builder General FAQ Documents concerning the IEC controller HPCD3.M6893 Programmable with the ControlEdge PCD Builder. CPU LIOs Communication Modules I/O modules Accessories
Documents Documents for Saia PCD QronoX General FAQ Documents concerning the IEC controller PCD3.M6893 Programmable with the Saia PCD® QronoX Engineering and Commissioning Suite. CPU LIOs Communication Modules I/O modules
Use caution when downloading FW to a PCD3.Mxxxx controller because it is possible downloading a wrong FW (e.g. the one for the PCD2.M480). Once the wrong FW is downloaded follow this procedure for downloading the correct FW:
work on port 2 on PCD3.M3x60 & PCD3.M5360. PCD3.M6860: Ping request from over rooter from different sub net is not respond. PCD3.M6860/M880: Profibus/S-IO/Profi-SBus does not work stable. PCD3.M [...] 2220-C15 Support of PCD2.M4x60 Support of PCD3.M3160/PCD3.M3360/PCD3.M5360 Support of PCD3.M6880, PCD3.T668 Standby-CPU-System Improvements PCD2.M4x6x, support Interrupt when reaching the [...] COSinus FW 1.28.37 was released as maintenance version for the systems: - PCD1.M0xx0/M2xx0, PCD2.M4x60, PCD3.Mxx60, PCD3.M6880 and PCD3.T665/T666/T668 . In June 2017: the COSinus FW 1
COSinus FW 1.28.37 was released as maintenance version for the systems: - PCD1.M0xx0/M2xx0, PCD2.M4x60, PCD3.Mxx60, PCD3.M6880 and PCD3.T665/T666/T668 . In June 2017: the COSinus FW 1.28.16 was introduced into production for the systems: - PCD1.M0xx0/M2xx0, PCD2.M4x60, PCD3.Mxx60, PCD3.M6880 and PCD3.T665/T666/T668 . the BACnet and LonIP FW 1.28.16 was put into production [...] the following PCD's with 8 MB onboard firmware memory: PCD1.M0xx0/M2xx0, PCD2.M4x60, PCD3.Mxx60, PCD3.M6880 and PCD3.T665/T666/T668 The table below does show the hardware dependencies in