The settings for Clock period High and Clock period low must be 2 / 150 same settings as for the PCD2.M480.
Is it possible to use the Siemens WinCC visualisation with SBC Classic PCD's? (FAQ #100508) Yes, the company "M [...] . S-Bus communication problems with PCD3 (FAQ #100336) Since the communiction on the PCD3 is not handled the same way [...] FBox libraries "Modbus 2" and "M-Bus" version 2.6.xxx (FAQ #101480) As described in FAQ 101479 the version 2.6.xxx of
The XOB 8 who is called when the firmware detects an invalid instruction (Invalid OPC) in the user program is no longer called on the systems Saia PCD® COSinus (PCD3, PCD2.M5, PCD2.M480).
In PG5 1.4.300 the new DP Master CPU without ethernet is not available, just the PCD3.M6540 can be selected
There is a difference in the "SBC Format" between "old" xx7 CPU's (PCD2.M127, 157, 177) and Saia PCD® COSinus based CPUs (PCD3, PCD2.M5xxx7 and PCD2.M487). The way to read analogue values from PCD2/3.W2xx and PCD2/3.W100, W3x0, W500 in the "SBC-Format" is not the same.
default with a spring clamp terminal block. Screw terminal blocks have to be ordered separately . PCD3 LIO and PCD2.M17x: to use addresses in the range 256 to 511, CPU's with production date 0331 [...] description of the exchangeable amount of data in the Profibus DP manual, a SBC-NT PLC (PCD3, PCD1.M2, PCD2.M5xxx, PCD2.M480) can communicate with a PCD3.T760 a maximum amount of 2'048 bytes [...] (degrees for temperature and e.g. mV for the voltage inputs). Procedure In the S-Net configurator, select a PCD3.W200 for the module where the PCD2.W220Z12 is plugged Select the format
default with a spring clamp terminal block. Screw terminal blocks have to be ordered separately . PCD3 LIO and PCD2.M17x: to use addresses in the range 256 to 511, CPU's with production date 0331 [...] description of the exchangeable amount of data in the Profibus DP manual, a SBC-NT PLC (PCD3, PCD1.M2, PCD2.M5xxx, PCD2.M480) can communicate with a PCD3.T760 a maximum amount of 2'048 bytes [...] (degrees for temperature and e.g. mV for the voltage inputs). Procedure In the S-Net configurator, select a PCD3.W200 for the module where the PCD2.W220Z12 is plugged Select the format
. PCD3.M5360: Power CPU with 2MByte program memory, 128MByte intflash, USB, Ethernet, RS-232, 4 IO slots, expandable up to 64 IO modules. Fupla: Status indicators of unconnected FBox [...] 101653 . Minimal firmware version for the Manager is 1.16.42 (PCD1.M2) and 1.16.45 (PCD2.M5 and PCD3), see FAQ 101640 . Minimal version of PG5 for configuring a PCD3.T665¦T666 is PG5 2.0 SP2 (PG5 [...] ’. This change has been made in order to be compatible with the Windows 10 start menu that’s accept only one level of folder. Device configurator: PCD3.M3160: Power CPU with 512kByte program
. PCD3.M5360: Power CPU with 2MByte program memory, 128MByte intflash, USB, Ethernet, RS-232, 4 IO slots, expandable up to 64 IO modules. Fupla: Status indicators of unconnected FBox [...] 101653 . Minimal firmware version for the Manager is 1.16.42 (PCD1.M2) and 1.16.45 (PCD2.M5 and PCD3), see FAQ 101640 . Minimal version of PG5 for configuring a PCD3.T665¦T666 is PG5 2.0 SP2 (PG5 [...] ’. This change has been made in order to be compatible with the Windows 10 start menu that’s accept only one level of folder. Device configurator: PCD3.M3160: Power CPU with 512kByte program
For BCU1 protocol not all communication interfaces of a PCD3 or a PCD2.M5540 can be used. On the other hand there is no problem using the newer FT1.2 protocol which is supported by all RS232 interfaces of the PCD3 and the PCD2.M5540.