CPU base units with on-board I/O and for up to 2 plug-in I/O modules Saia PCD1.Room with Ethernet TCP/IP for room automation and heavac applications, web and FTP server, file system, CPU with 256 KByte user program (RAM), backup memory, on-board 8 MByte Flash memory, USB port for PG5, up to 40 I/O, 1 free I/O module socket, on-board I/O (with fixed ..W525 on I/O slot 1) : - 2 interrupt inputs, 1 output (PWM) - 12 digital I/O (4I/4O/4 configurable) - 8 analogue I/O (6I/2O), clock (RTC), data protection 1-3 years, RS-485 (up to 115 kbits/s), 1 port (socket A) for PCD
E-Line CPU PCD1.M2220-C15 Freely programmable Supply 24 VAC/VDC Web and FTP server, filesystem 512 kByte memory for application program 128 kByte FRAM memory for R/F/T/C/DB/Text 128 MByte flash-memory No battery, but backup of R/F/T/C/DB/Text with FRAM technology (the data are retained in a de-energised state) 2 I/O Slots for PCD2 I/O modules (maximum of 39 I/O's directly on a PCD PCD1.M2200-C15) 1 Slot for 'M' memory module
SSI interface module for absolute encoder for Saia PCD1 and PCD2 controllers Absolute encoder module with SSI interface and 4 outputs 24 VDC/0.5 A
Saia PCD® E-Line programmable modules Programmable E-Line input/output module for analogue applications supply 24 VAC/VDC 4 analogue inputs 12 bits 0…10 V, ±10 V, 0(4)…20 mA, Pt/Ni 1000, NTC, 0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm 4 analogue outputs 12 bits, 0…10 V (4 mA max.) 2 interfaces: RS-485 (S-Bus), micro USB for PG5
Saia PCD® E-Line programmable modules Programmable E-Line input/output module for light and sunblind control supply 24 VAC/VDC 4 digital inputs 24 VAC/VDC 2 relay changeover 230 VAC / 30 VDC, 8 A, max. inrush current 15 A, incl. galvanically isolated current measurement 2 analogue outputs 12 bits, 0…10 V (3 mA max.) 2 interfaces: RS-485 (S-Bus), uUSB for PG5
Plug-in terminal blocks for PCD3 I/O modules Plug-in I/O spring terminal block, 4-pole up to 2.5 mm2, labelled 1 to 4, for light and shade control module PCD3.A860, connector type "G"
Plug-in terminal blocks for PCD3 I/O modules Plug-in spring terminal block, 2x5-pole up to 1.0 mm2 (black block), also for PCD2.G200, connector type "KB"
Plug-in terminal blocks for PCD3 I/O modules Plug-in spring terminal block, 2x5-pole up to 1.0 mm2 (orange block), labelled 0 to 9, also for PCD2.G200, connector type "K";
PQA - Saia PCD® Power Quality Analyser Power Quality Analyser (PQA) with RS-485 interface LCD 128 x 64 monochrome 1.9" LED for I/O and status supply 110…230 VAC 50/60 Hz measuring inputs 3PH+N up to 270 VAC 1 digital input 24 VDC, high active 1 digital output 5…24 VDC 2 relay normally open 230 VAC, 6 A (resistive load) 1 analogue input for Pt/Ni 1000 sensor 1 interface RS-485 (S-Bus/Modbus) with galvanic isolation
PCD7.F1xxS communication modules - 1 × CAN galvanic separated - 1 × USB Device port for programming and service - 1 × USB host 2 × interrupt inputs - 1 × watch dog relay - extendable up to 1023 I/O Supported PCD3 - I/O Modules: - Connector for I/O Extension PCD3.C200 - Starting with firmware 0.0.0.281: PCD3.Ax, …Ex, …W3x5, …W6x5 [...] Saia PCD3.M6893 - IEC Controller The most recent cyber security level (ANSI ISA 62443 – SL3/SL4) enables the use in mission critical and IoT / Cloud applications. Main features - PCD