library version 2.6.200 for the PCD7.L60x can be "grouped by function" in the FBox selector window of PG5 2.0.200. PCD7.L602 and L603 delivered until summer 2010 were sensitive to crossed [...] 2015). The PCD7.L60x Room controller library 2.5.166 / 2.6.166 contains a modification explained in FAQ 101514 . The PCD7.L60x Room controller library 2.5.165 / 2.6.165 contains a correction explained in FAQ 101506 . The PCD7.L60x Room controller library 2.5.101 / 2.6.151 contains a correction explained in FAQ 101455 . In May 2009 the wiring of the
Documentation Software Good to know The FBox library version 2.6.200 for the PCD7.L60x can be "grouped by function" in the FBox selector window of PG5 2.0.200. The PCD [...] sensor to the S or E2 terminal. If a PT1000 temperature sensor is connected to the S terminal of a PCD7.L60x room controller, then all the time the temperature value will be used/shown, which is [...] FBox family 'RoomControler PCD7_60x V2' does need to have a decimal value without decimal point. (for an output value of 8.3 V the decimal value 83 have to be set) This FBox allows the manual
sensor to the S or E2 terminal. If a PT1000 temperature sensor is connected to the S terminal of a PCD7.L60x room controller, then all the time the temperature value will be used/shown, which is [...] FBox family 'RoomControler PCD7_60x V2' does need to have a decimal value without decimal point. (for an output value of 8.3 V the decimal value 83 have to be set) This FBox allows the manual [...] version 2.6.165. Symptom After having changed the operation mode of a PCD7.L60x Room controller from "autonomous" to "slave" the output values for the heating and cooling signal are not
Documentation Software Good to know The FBox library version 2.6.200 for the PCD7.L60x can be "grouped by function" in the FBox selector window of PG5 2.0.200. The PCD [...] sensor to the S or E2 terminal. If a PT1000 temperature sensor is connected to the S terminal of a PCD7.L60x room controller, then all the time the temperature value will be used/shown, which is [...] FBox family 'RoomControler PCD7_60x V2' does need to have a decimal value without decimal point. (for an output value of 8.3 V the decimal value 83 have to be set) This FBox allows the manual
guaranteed until end of 2013. The differences between the PCD7.L79x and PCD7.L79xN are described in the following document. There is a program example for the PCD7.L79xN available in the Getting Started section . PCD7.L79x units delivered until summer 2010 were sensitive to crossed polarity of the AC Power supply ( see link ). This is no longer the case with hardware version 2.0. [...] Product Category Archive Room Controller PCD7.L79x General
Comparision. There is a program example for the PCD7.L79xN available in the Getting Started section . The minimal FBox library version is 2 [...] sensor to the S or E2 terminal. If a PT1000 temperature sensor is connected to the S terminal of a PCD7.L60x room controller, then all the time the temperature value will be used/shown, which is [...] FBox family 'RoomControler PCD7_60x V2' does need to have a decimal value without decimal point. (for an output value of 8.3 V the decimal value 83 have to be set) This FBox allows the manual
controller and a Saia PCD Supervisor Good to know To use the PCD7.LRxx-P5 programmable room controller you need minimum the versions: PG5: PG5.2.3.113 Version or higher [...] Documentation Room operation units DALI64 Lighting system PG5 2.3, DALI64 template project for programmable room controller PCD7.LRxx-P5 The following project templates can be used with PG5 2.3 or newer Install the template from Project-Configutator with "Restore project..." PG5 2.3, TR80 modbus template project for programmable room controller PCD
BACnet specific information The BTL certificate for: PCD7.LRL2, PCD7.LRS4, PCD7.LRS5 is stored here : App software for Android devices Firmware for PCD7.LRxx BACnet Room controllers Room operation units Good to know To use the PCD7.LRxx BACnet Room controller you need minimum the versions: PG5: PG5.2.2.200 Version or [...] 5 application program toggles cyclically a Flag where the Flag is mapped to a BACnet BI object ‘PCD-Input reference’ 2. If the BACnet stack is running, then the BACnet stack copies the ‘PCD-Input reference’ of
The RIO modul PCD7.L100 / L 200 doesn't respond. It is frozen , all the LED are switch off and it doesn't communicate anymore! After a powerup the RIO communicates again properly. This phenomenon occurs in an enironment with electronmagnetic noises. The very new PCD7.Lx00 have a filter which cures that problem. If it isn't possible to reduce the noises, try to change the PCD7.Lx00 module, the new one should be at least of the version S 18 (stamp on the modul).
PCD7 Why I have a blue screen after a panel reboot on WES7 panel after activation of the HORM mode (Hibernate Once ResumeMany)? (FAQ #101976) You have a PCD [...] Product Category Remote I/O PCD7.Lxxx S-Bus RIO General