least the PG5 firmware downloader version 2.1.311 or newer (included in PG5 patch 2.1.311 or newer) to prevent the loading of the FW 1.24.xx to a not compatible PCD. Firmware 1 [...] used as destination. STXMX / SRXMX instructions are working correctly. I/O modules: - PCD2.G200: temperature is correctly calculated when Ni100 L&S is selected - PCD2/3.W380: support for [...] SASI mode (MC2) does not work on PCD2.M5xx0 port 2 If the a Smart RIO or Smart RIO manager is disabled with the tag, the manager still sends the configuration to the RIO The Program Restore when
This firmware could be used as maintenance firmware for PCD's with 8 MB firmware memory. Do use at least the PG5 firmware downloader version 2.1.311 or newer (included in PG5 patch 2.1.311 or newer) to prevent the loading of the FW 1.24.xx to a not compatible PCD.
FW for the pWeb-Panel PCD7.D4xxxT5. This firmware does support the module PCD7.R610 Do use at least the PG5 firmware downloader version 2.1.311 or newer (included in PG5 patch 2.1.311 or newer) to prevent the loading of the FW 1.24.xx to a not compatible PCD.
This firmware is used in the PCD production and the PCD's are shipped with this firmware. Do use at least the PG5 firmware downloader version 2.1.311 or newer (included in PG5 patch 2.1.311 or newer) to prevent the loading of the FW 1.24.xx to a not compatible PCD.
On a Profi S-Bus network when PCD7.D76_ terminals are connected to PCD3.Mxxx or PCD2.M480 PLC's over Profi S-Bus, the terminal loses the communication after some time and get even frozen. This problem is corrected in the new boot, FW and driver. The PCD8.D81 V 5.09 is needed , the attached files have to be copied in it (see procedure below). It is also necessary to update the PCD3.Mxxx and PCD2.M480 FW with the version PCD3.Mxxx_023.blk / PCD2.M480_$27 or newer! Ask the PCD technical support or your representation for it!
The product line PCD7.D8xx has been discontinued. As replacement it is recommended to use a VGA S-Web PCD7.D410V panel and taking advantage of the integrated WebServer of the PCD. PCD7 / D8xx Why has the VT Win project such a [...] bigger (100-200MBytes). Problem The size of the project increase after storing to a really hughe size. Reason If unicode fonts are used which are not present in the PC
PCD7.F1xxS Serial interface modules Documentation Good to know The PCD7.F1xxS modules with hardware version A can not be used on non Saia PCD® COSinus systems (PCD1.M1xx, PCD2.M1xx, PCS1), see FAQ 101743 . The PCD7.F1xx modules will be replaced by the fully compatible PCD7.F1xxS modules (fully [...] Product Category Programmable controller PLC Accessories Communication Modules PCD
7.T160 D-Sub 9pin on PCD Port 2 on PCD3.M3 and M6 A=RxD /TxD-N green D pin 8 D B=RxD /TxD-P red D/ pin 3 /D Example [...] 3): PCD3.M5540 (D-Sub "S-Net", port 3) PCD2.M5540, X3, port2 equipped with a PCD7.F110 pin 3 terminal 2 pin 8 terminal 1 [...] PG5 2.0 / Profibus FMS Why after a SASI
7/Step7, report available below) Good to know In June 2006 the new IP communication module SBC PCD7.F655 has been released. This module is equipped with a new IP stack that, among other improvements, increases communication performance. The hardware of this new module is identical to the hardware of the PCD7.F650. It is therefore possible upgrading a PCD7.F650 to a PCD7.F655. The functionality [...] Product Category Programmable controller PLC Accessories Communication Modules PCD
points. The PCD2 can be expanded by means of plug-in memory modules to become a Lon IP® or BACnet®-enabled controller. The PCD2 has communication interfaces such as USB, Ethernet, RS-485 and Automation [...] ? (FAQ #102040) Due to a production error it's possible that PCD2.M5540 which have been produced in 2020 may contain a [...] MC5 mode on F2xxx module All PCD’s: RS485 driver keep holding bus after a while All PCD’s: Http request ‘is modified’ is not handled correctly on the PCD Web-Server which lead to the effect that