Saia PCD3 Wide Area Controller Modem PCD3.M2x30A4T5 with GSM/GPRS modem PCD3.M2330A4T1 with PSTN modem PCD3.M2330A4T3 with ISDN modem
Saia PCD3 Wide Area Controller Modem PCD3.M2x30A4T5 with GSM/GPRS modem PCD3.M2330A4T1 with PSTN modem PCD3.M2330A4T3 with ISDN modem
PCD4 conversion kit for connecting the PCD4 I/O level to a PCD2.M5xxx or PCD3.M3xxx/5xxx series CPU>
.06.2019 #102031 - On a PCD3.M6860 it’s possible to use BACnet on the Ethernet port ETH1 and/or on ETH2 [...] ? 08.12.2017 #102013 - Why after an download of a PG5 2.2.230 project to the PCD, where BACnet revision 14 is used, the application program on the PCD doesn’t work [...] ? 29.11.2017 #102008 - PG5 2.1 and PG5 2.2 with S-Bus communication library 2.7.370, why the S-Bus communication on the master PCD stops either after a certain time or
BACnet specific information The BTL certificate for: PCD7.LRL2, PCD7.LRS4, PCD7.LRS5 is stored here : App software for Android devices Firmware for PCD7.LRxx BACnet Room controllers Room operation units Good to know To use the PCD7.LRxx BACnet Room controller you need minimum the versions: PG5: PG5.2.2.200 Version or [...] 5 application program toggles cyclically a Flag where the Flag is mapped to a BACnet BI object ‘PCD-Input reference’ 2. If the BACnet stack is running, then the BACnet stack copies the ‘PCD-Input reference’ of
controller and a Saia PCD Supervisor Good to know To use the PCD7.LRxx-P5 programmable room controller you need minimum the versions: PG5: PG5.2.3.113 Version or higher [...] Documentation Room operation units DALI64 Lighting system PG5 2.3, DALI64 template project for programmable room controller PCD7.LRxx-P5 The following project templates can be used with PG5 2.3 or newer Install the template from Project-Configutator with "Restore project..." PG5 2.3, TR80 modbus template project for programmable room controller PCD
In the FPGA version HC3 of the PCD2.H110 there is a small bug: The LEDs for the CCO (Counter Controlled Output) and TCO (Timer Controlled Output) aren't working. However, CCO and TCO are working correctly, only the LEDs are affected. The bug is corrected in FPGA version HC4.
Comparision. There is a program example for the PCD7.L79xN available in the Getting Started section . The minimal FBox library version is 2 [...] sensor to the S or E2 terminal. If a PT1000 temperature sensor is connected to the S terminal of a PCD7.L60x room controller, then all the time the temperature value will be used/shown, which is [...] FBox family 'RoomControler PCD7_60x V2' does need to have a decimal value without decimal point. (for an output value of 8.3 V the decimal value 83 have to be set) This FBox allows the manual
. The differences between the PCD7.L79x and PCD7.L79xN are described in the following document. There is a program example for the PCD7.L79xN available in the Getting Started section . PCD7.L79x units delivered until summer 2010 were sensitive to crossed polarity of the AC Power supply ( see link ). This is no longer the case with hardware version 2.0. [...] Product Index Archive PCD7 Lxxx: RIOs and Room Controllers L
Documentation Software Good to know The FBox library version 2.6.200 for the PCD7.L60x can be "grouped by function" in the FBox selector window of PG5 2.0.200. The PCD [...] sensor to the S or E2 terminal. If a PT1000 temperature sensor is connected to the S terminal of a PCD7.L60x room controller, then all the time the temperature value will be used/shown, which is [...] FBox family 'RoomControler PCD7_60x V2' does need to have a decimal value without decimal point. (for an output value of 8.3 V the decimal value 83 have to be set) This FBox allows the manual