feature a label creator for the I/Os on the RIO. Latest maintenance firmware version Good to know The PCD3.T660 will be discontiued by the end of 2012. The repair service for the PCD [...] -S-I/O communication protocol and can be programmed. When replacing the PCD3.T660 Ethernet RIO with a PCD3.T665 or PCD3.T666 , the user program of the Manager has to be adapted [...] . Why doesn't the PCD3.T660 accept any configuration anymore? (FAQ #101289) In case the Ethernet RIO stays in a state
101653 . Minimal firmware version for the Manager is 1.16.42 (PCD1.M2) and 1.16.45 (PCD2.M5 and PCD3), see FAQ 101640 . Minimal version of PG5 for configuring a PCD3.T665¦T666 is PG5 2.0 SP2 (PG5 2.0.200). When replacing a PCD3.T660 by a PCD3.T665 the user program needs to be adapted accordingly. I/O modules: The I/O modules are delivered per default with a spring clamp terminal [...] RIO PCD3.T66x there is a diagnostic flag available which can be used to detect whether the RIO Manager CPU is exchanging data with the RIO. However, when using PG5 2.0.200 this flag is not correctly
(degrees for temperature and e.g. mV for the voltage inputs). Procedure In the S-Net configurator, select a PCD3.W200 for the module where the PCD2.W220Z12 is plugged Select the format [...] default with a spring clamp terminal block. Screw terminal blocks have to be ordered separately . PCD3 LIO and PCD2.M17x: to use addresses in the range 256 to 511, CPU's with production date 0331 [...] information of a PCD3.W745 on a PCD3.T760? (FAQ #101697) When the 4 channels analog carte PCD2.W745 is used on a PCD3.T760 RIO
Measurement parameter: - 0…10V - 0…2.5V - 0…20 mA - Pt/Ni1000 (default) - Pt1000: –50…+400°C - Ni1000: –50…+200°C
Measurement parameter: - 0…10V - 0…2.5V - 0…20 mA - Pt/Ni1000 (default) - Pt1000: –50…+400°C - Ni1000: –50…+200°C
of the PCD3.M6860. In PG5 it’s possible to activate at the same time BACnet on ETH1 and ETH2 but we strongly recommend to use/activate BACnet only on one of the two Ethernet ports to avoid a [...] be loaded again). All PCD1.M2 and PCD2.M5 systems can be equipped with a firmware 1.16. and more recent [...] address bound to an IP address. Does a PCD generate gratuitous ARP telegrams? No, a PCD (e.g. a PCD3, a PCD2.M5xxx or a PCD equipped with a PCD7.F655) does not generate gratuitous ARP telegrams when
After import a PCD4.M145 project on a PCD4.M170, the port 0 doesn't work anymore. The PCD4.M170 doesn't have the posibility like the PCD2.M170 to use the port 0 in RS 485 only in RS 232. Because those 2 PCD have the same FW, in order to use the port 0 on a PCD4.M170 in RS 232, it has to be configured: In IL, the SOCL instruction is necessary In Fupla, in the SASI Slave Fbox choose RS Typ RS 232 (not default)
. When updating from a PCD6.M1/M2 CPU to a PCD6.M3, the memory module as well and the firmware versions of all CPU's had to match (for more details please refer to the attached document.). The update to [...] . Systems introduced before 2003: All PCD1, PCD2 (except PCD2.M480), PCD4 and PCD6 as well as PCS1 classic contollers do have a baud rate limitation of 38.4 kB/s on each serial port. For [...] (PCD2.M480 and PCD3.xxxx): Due to faster hardware there are much higher baud rates possible on the serial ports (up to 115 kB/s)! There is only one restriction regarding UART sharing left: On a PCD
. When updating from a PCD6.M1/M2 CPU to a PCD6.M3, the memory module as well and the firmware versions of all CPU's had to match (for more details please refer to the attached document.). The update to [...] . Systems introduced before 2003: All PCD1, PCD2 (except PCD2.M480), PCD4 and PCD6 as well as PCS1 classic contollers do have a baud rate limitation of 38.4 kB/s on each serial port. For [...] (PCD2.M480 and PCD3.xxxx): Due to faster hardware there are much higher baud rates possible on the serial ports (up to 115 kB/s)! There is only one restriction regarding UART sharing left: On a PCD