MC5 mode on F2xxx module All PCD’s: RS485 driver keep holding bus after a while All PCD’s: Http request ‘is modified’ is not handled correctly on the PCD Web-Server which lead to the effect that [...] (CVE-2017-9628) All PCD's: The Modbus CSF CloseSRPort does not free the port then a open/SASI call give an error and the port does not work. PCD1.M2xx0 PCD1.M22x0 PCD2.M4x60: PCD can crash while power down [...] SRPort does not free the port then a open/SASI call give an error and the port does not work. PCD1.M2xx0 PCD1.M22x0 PCD2.M4x60: PCD can crash while power down when XOB 0 is programmed. PCD1.M2xx0 PCD
repaired. The PCD4.U100 upgrade kit can be used in order to replace the CPU of a PCD4 installation by a PCD3 or a PCD2.M5 (while keeping the PCD4 I/Os). Please note that PCD7.R400 modules [...] (or in case a PC is used, by interpreting the tracewin files). This phenomenon can be observed on PCD1.M1x5, PCD2.M150, PCD2/4.M170 and PCS1 systems (with firmware which are supporting the "Secure S [...] appears if the used firmware on the CPU does not support the "active and non ACK" filter for the S-Web alarming functionality (e.g. a PCD2.M150 with firmware 0D3). Symptom Instead of the
applications the usage of a PCD1.M2xx0 could also be considered [...] F1). Why does my PCD1 no longer start (due to a "Text segment error") after downloading a project with PG5 2.0? (FAQ #101379) On PCD1.M1x0 or a PCD2.M110/120 with old firmware version the CPU won't go in run anymore after downloading the project with PG5 2.0.110. Symptom As soon as the program is downloaded
applications the usage of a PCD1.M2xx0 could also be considered [...] F1). Why does my PCD1 no longer start (due to a "Text segment error") after downloading a project with PG5 2.0? (FAQ #101379) On PCD1.M1x0 or a PCD2.M110/120 with old firmware version the CPU won't go in run anymore after downloading the project with PG5 2.0.110. Symptom As soon as the program is downloaded
PCD2.W525 module is already plugged on delivery. If this module is missing, the controller doesn’t go into RUN-mode! With a PCD FW>1.22.25 a maximum of 10 selectable addresses are allowed. Check [...] other input? (FAQ #102007) With some specific sensor and configuration, the inputs of a module PCD2/3.W525 could perturbate an other input of the same module Module PCD2/3.W525 are not designed as other analog input modules (as PCD2/3.W340 or W200 for example). Particularities of the module W525 are the following
version 005 can be found on the PCD4.M1x0 pages. PCD4.M340 (obsolete): CPU0 has got the same firmware as a PCD4.M1x0, the latest version 005 can be found on the PCD4.M1x0 pages. CPU1 with LAN2 has the [...] (or in case a PC is used, by interpreting the tracewin files). This phenomenon can be observed on PCD1.M1x5, PCD2.M150, PCD2/4.M170 and PCS1 systems (with firmware which are supporting the "Secure S [...] appears if the used firmware on the CPU does not support the "active and non ACK" filter for the S-Web alarming functionality (e.g. a PCD2.M150 with firmware 0D3). Symptom Instead of the
4.M340 (obsolete): CPU0 has got the same firmware as a PCD4.M1x0, the latest version 005 can be found on the PCD4.M1x0 pages. CPU1 with LAN2 has the same firmware as a PCD6.T1xx, last version 005, only available on [...] (or in case a PC is used, by interpreting the tracewin files). This phenomenon can be observed on PCD1.M1x5, PCD2.M150, PCD2/4.M170 and PCS1 systems (with firmware which are supporting the "Secure S [...] appears if the used firmware on the CPU does not support the "active and non ACK" filter for the S-Web alarming functionality (e.g. a PCD2.M150 with firmware 0D3). Symptom Instead of the
The SBC PCD1.M2xxx series is a compact controller with onboard I/Os and in addition two I/O-slots for PCD2 I/O-modules or communication interface-modules. The Web/IT functionality, the onboard memory [...] used for working with the PCD1.M2160. PG5 2.0.200 or later is to be used for working with the PCD1.M2020. Patch 4 of PG5 2.0.150 is to be used for working with the PCD1.M2120, see FAQ 101541 [...] The differences between firmware version 1.14.23 and 1.16.27 are listed in FAQ 101624 . Please note that the Micro SD card inside the PCD1.M2 is NOT to be removed! On slot A can only be
of the PCD3.M6860. In PG5 it’s possible to activate at the same time BACnet on ETH1 and ETH2 but we strongly recommend to use/activate BACnet only on one of the two Ethernet ports to avoid a [...] be loaded again). All PCD1.M2 and PCD2.M5 systems can be equipped with a firmware 1.16. and more recent [...] address bound to an IP address. Does a PCD generate gratuitous ARP telegrams? No, a PCD (e.g. a PCD3, a PCD2.M5xxx or a PCD equipped with a PCD7.F655) does not generate gratuitous ARP telegrams when
Why on a PCD3.M5/6xxx or a PCD2.M45xx the battery LED is switched on and the battery error message is activated in the application program after a new battery was inserted? (FAQ #102039) [...] . On a PCD3.M6860 it’s possible to use BACnet on the Ethernet port ETH1 and/or on ETH2? (FAQ #102031) Yes it’s [...] one of the two Ethernet ports to avoid a bad behavior on BACnet. The activation and selection of the used Ethernet port for BACnet communication on the PCD3.M6860 is done in PG5 2.2 or PG5 2