controller and a Saia PCD Supervisor Good to know To use the PCD7.LRxx-P5 programmable room controller you need minimum the versions: PG5: PG5.2.3.113 Version or higher [...] Documentation Room operation units DALI64 Lighting system PG5 2.3, DALI64 template project for programmable room controller PCD7.LRxx-P5 The following project templates can be used with PG5 2.3 or newer Install the template from Project-Configutator with "Restore project..." PG5 2.3, TR80 modbus template project for programmable room controller PCD
Comparision. There is a program example for the PCD7.L79xN available in the Getting Started section . The minimal FBox library version is 2 [...] sensor to the S or E2 terminal. If a PT1000 temperature sensor is connected to the S terminal of a PCD7.L60x room controller, then all the time the temperature value will be used/shown, which is [...] FBox family 'RoomControler PCD7_60x V2' does need to have a decimal value without decimal point. (for an output value of 8.3 V the decimal value 83 have to be set) This FBox allows the manual
guaranteed until end of 2013. The differences between the PCD7.L79x and PCD7.L79xN are described in the following document. There is a program example for the PCD7.L79xN available in the Getting Started section . PCD7.L79x units delivered until summer 2010 were sensitive to crossed polarity of the AC Power supply ( see link ). This is no longer the case with hardware version 2.0. [...] Product Category Archive Room Controller PCD7.L79x General
Documentation Software Good to know The FBox library version 2.6.200 for the PCD7.L60x can be "grouped by function" in the FBox selector window of PG5 2.0.200. The PCD [...] sensor to the S or E2 terminal. If a PT1000 temperature sensor is connected to the S terminal of a PCD7.L60x room controller, then all the time the temperature value will be used/shown, which is [...] FBox family 'RoomControler PCD7_60x V2' does need to have a decimal value without decimal point. (for an output value of 8.3 V the decimal value 83 have to be set) This FBox allows the manual
sensor to the S or E2 terminal. If a PT1000 temperature sensor is connected to the S terminal of a PCD7.L60x room controller, then all the time the temperature value will be used/shown, which is [...] FBox family 'RoomControler PCD7_60x V2' does need to have a decimal value without decimal point. (for an output value of 8.3 V the decimal value 83 have to be set) This FBox allows the manual [...] version 2.6.165. Symptom After having changed the operation mode of a PCD7.L60x Room controller from "autonomous" to "slave" the output values for the heating and cooling signal are not
Documentation Software Good to know The FBox library version 2.6.200 for the PCD7.L60x can be "grouped by function" in the FBox selector window of PG5 2.0.200. The PCD [...] sensor to the S or E2 terminal. If a PT1000 temperature sensor is connected to the S terminal of a PCD7.L60x room controller, then all the time the temperature value will be used/shown, which is [...] FBox family 'RoomControler PCD7_60x V2' does need to have a decimal value without decimal point. (for an output value of 8.3 V the decimal value 83 have to be set) This FBox allows the manual
library version 2.6.200 for the PCD7.L60x can be "grouped by function" in the FBox selector window of PG5 2.0.200. PCD7.L602 and L603 delivered until summer 2010 were sensitive to crossed [...] 2015). The PCD7.L60x Room controller library 2.5.166 / 2.6.166 contains a modification explained in FAQ 101514 . The PCD7.L60x Room controller library 2.5.165 / 2.6.165 contains a correction explained in FAQ 101506 . The PCD7.L60x Room controller library 2.5.101 / 2.6.151 contains a correction explained in FAQ 101455 . In May 2009 the wiring of the
points. The PCD2 can be expanded by means of plug-in memory modules to become a Lon IP® or BACnet®-enabled controller. The PCD2 has communication interfaces such as USB, Ethernet, RS-485 and Automation [...] ? (FAQ #102040) Due to a production error it's possible that PCD2.M5540 which have been produced in 2020 may contain a [...] MC5 mode on F2xxx module All PCD’s: RS485 driver keep holding bus after a while All PCD’s: Http request ‘is modified’ is not handled correctly on the PCD Web-Server which lead to the effect that
7/Step7, report available below) Good to know In June 2006 the new IP communication module SBC PCD7.F655 has been released. This module is equipped with a new IP stack that, among other improvements, increases communication performance. The hardware of this new module is identical to the hardware of the PCD7.F650. It is therefore possible upgrading a PCD7.F650 to a PCD7.F655. The functionality [...] Product Category Programmable controller PLC Accessories Communication Modules PCD
7.T160 D-Sub 9pin on PCD Port 2 on PCD3.M3 and M6 A=RxD /TxD-N green D pin 8 D B=RxD /TxD-P red D/ pin 3 /D Example [...] 3): PCD3.M5540 (D-Sub "S-Net", port 3) PCD2.M5540, X3, port2 equipped with a PCD7.F110 pin 3 terminal 2 pin 8 terminal 1 [...] PG5 2.0 / Profibus FMS Why after a SASI