happen with other SSI encoders. PCD2.H110: This product is obsolet. Only for NT Systems (PCD2/3.Mxxxx) exist a replacement PCD2.H112/H114 and PCD3.H112/H114 [...] Documentation Software Technical reports Good to know PCD2.H150: If you are using MTS Temposonic linear encoders, make sure to either read the position continuously or to read it [...] Product Category Programmable controller PCD3: CPUs, cassette design Hxxx: Counting and motion H
PCD6.E100, PCD6.E610, PCD6.E611 or PCD6.A350 (FAQ #100264) These 4 digital I/O cards have all an address [...] . Nevertheless it is possible measuring the range 0..20 mA with the analogue input modules for PCD systems. Why do the SBC input modules have a range of 0..20 mA? One advantage of measuring the [...] the used power supply does not have the +/-15V the analogic carts can not work. With the PCD4/6.N200 supply it is not possible to use analogic cards. You will need the PCD4/6.N210 supply
PCD6.E100, PCD6.E610, PCD6.E611 or PCD6.A350 (FAQ #100264) These 4 digital I/O cards have all an address [...] . Nevertheless it is possible measuring the range 0..20 mA with the analogue input modules for PCD systems. Why do the SBC input modules have a range of 0..20 mA? One advantage of measuring the [...] the used power supply does not have the +/-15V the analogic carts can not work. With the PCD4/6.N200 supply it is not possible to use analogic cards. You will need the PCD4/6.N210 supply
The version of PG5 1.4 200 doesn't contain the latest HMI Library needed for programming the PCD7.D290 Display. Unzipp the attached file and run the 2 exe files (HMI editor 14210 and library 14211) Don't apply these files in case PG5 1.4.30
When an element is configured as Integer with the format ##### (without dot) the value of the register is wrongly displayed on the terminal. This is a FW bug in the actual version of the PCD3.M_ and PCD2.M480.
, Webconnect software to do the conversions from the PCD format to a browser conform format, file handling by firmware Web.Builder Classic software, PCD2.M170 , PCD3.Mxxxx , PCD4.M170 , PCD2 [...] 7.D7xx , software PCD8.D81W Terminals PCD7.D7xx , software PCD8.D81W When a lot of trend or history functions are required, a PC-based solution is more appropriate [...] used together with our OPC server Saia®Visi.Plus is a powerful and flexible tool, that is well integrated in the PCD Classic world Saia®Visi.Plus as mentioned above We don
By default there are 12 listener sockets defined on the Web Server of a PCD. This means that simuntaneously 12 Web browsers can communicate with the S-Web server. The connection of a 13th browser would be disconnected directly. This number can be extended to 24 listener sockets in the Device Configurator from PG5 2.0 SP1 or later. This means that there's still an upper limit. There's a way to define this 'unlimited' number of connection.
The FBox "Initialisation 2.0" from the DDC Suite FBox library has a "WD" input. When activated, this will close the onboard watchdog relay of the PCD (and open it if an error on the PCD occurs or if the user program takes more than 250 ms to be executed).
A 2,2 voltage of the battery is sufficient to keep the content of the SRAM memory of the PCD even if the PCD is not powered on with the 24VDC. At power-up, the PCD checks if the battery or supeCAP voltage is less than 2.2. volt, and tests some patterns and signatures in the SRAM. If one of those test gives an error the content of the SRAM is deleted, the PCD clock is reinitialized. If a Program Backup is available, a restore is done.
Since BACnet objects vary heavily in the amount of properties and features it is not possible to define a number of supported BACnet objects per CPU. However, this FAQ contains a rule of thumb for the amount of BACnet objects that can be defined on a PCD3 or a PCD2.M5xx0.