(PCD7.D776 Rev. 3) or by a hardware modification (PCD7.D776 Rev. 2). For updating the boot- and firmware version, please use the PCD8.D81W ( VTWIN) version 5.18 (or newer) which can be optained from [...] (port 0) of a PCD2.M110 (or a PCD2.M120) but not on the following systems: PCS1, PCD2.M150/M170/M480/M5xx0 or on a PCD3. Reason The PGU mode of recent PCD systems is no longer based on the P [...] .M150 and PCD2.M170: Modify your communication cable (Pin 6 should not be used, Pin 6 of PGU port =0). In the PCD program you need to add a "SASI Slave Mode D" with the parameters: RS 232, 9600, Parity, 7
: BACnet revision 14 requires a PCD and BACnet FW >= 1.28.xx. The PCD and BACnet FW >= 1.28.xx does not support BACnet revision 9. BACnet revision 9 requires a PCD and BACnet firmware = 2.3.196 can no [...] 5 Online configurator? (FAQ #102040) Due to a production error it's possible that PCD2.M5540 which have been produced in [...] ) On a PCD3.M6860 it’s possible to use BACnet on the Ethernet port ETH1 and/or on ETH2? (FAQ #102031) Yes it’s
: BACnet revision 14 requires a PCD and BACnet FW >= 1.28.xx. The PCD and BACnet FW >= 1.28.xx does not support BACnet revision 9. BACnet revision 9 requires a PCD and BACnet firmware = 2.3.196 can no [...] 5 Online configurator? (FAQ #102040) Due to a production error it's possible that PCD2.M5540 which have been produced in [...] ) On a PCD3.M6860 it’s possible to use BACnet on the Ethernet port ETH1 and/or on ETH2? (FAQ #102031) Yes it’s
.1xx must be installed again in PG5 2.2.2xx. BACnet revision 14: BACnet revision 14 requires a PCD and BACnet FW >= 1.28.xx. The PCD and BACnet FW >= 1.28.xx does not support BACnet revision 9 [...] Browser Panel: 1.18.28 Please also respect the PCD hardware dependency; a recent PCD3 firmware version that is required (see firmware download page). The "Alarming 2" feature is only supported on Saia PCD [...] to the panel is on OFF mode. 2.- The only panels where it is possible to re-activate such remote access are : PCD7.D412DTPx and PCD7.D4xxxT5F. All the others (a part from someOEMs) do not
with PG5 V2.1.200, but not back again Once a project has been opened with PG5 V2.1.200, it is not possible to open it again with the previous versions. As this new version contains no major changes [...] diagnostic information of a PCD3.W745 on a PCD3.T760? (FAQ #101697) When the 4 channels analog carte PCD2.W745 is used on a [...] ): Why does my PCD7.F7500 not work on my PCD2.M5540? (FAQ #101655) In some cases it is possible that a PCD7.F7500 is not
Configuration Manual: Saia PCD® Supervisor V2.0 Version XXX04: - Chapt. 6.3.6 “Enhanced PG5 Import Wizard” added - Chapt. 6.6.7 “New Px / responsiv elements” added - Chapt. 7.4 “HTML 5 Enhancements” added - Chapt. 7.4.1 “New reporting functions” added - Chapt. 7.5 “Cloud connector” added - Chapt. 7.6 “Bulk deploy” added - Chapt. 7.7 “VykonPro modules“ added - Chapt. A.4 “What is in V1.2 new” added - Chapt. A.5 “What is in V2.0 new” added - Chapt. A.6 “What will come with version V2.1” added Version XXX05: - Chapt. 3.15 “General Data Protection Regulation(GDPR)” added
English: This patch solve a issue in relation to Saia PCD Supervisor installations having multiple IP Interface adapters installed. The problem could occur after a station restart, and lead to [...] interfaces on PC platforms). In these cases, another available interface or no interface may be used for that station. Patch is working for Saia PCD Supervisor 2.1 and 3.0 Deutsch: Der Patch behebt ein Problem auf Saia PCD Supervisor-Installationen bei welchen mehrere IP-Interface-Adaptern installiert sind. Das Problem könnte nach einem Neustart der Station auftreten, und bewirken dass die
1 CPU base units with on-board I/O and for up to 2 plug-in I/O modules Modular room controllers Saia®PCD1.Room Saia® PCD1.Room with Ethernet TCP/IP Covers for PCD1.M2xxx E-Line CPU PCD1.M2220-C15 The Saia PCD® controller PCD1.M2200-C15 functions as a master for the attached modules. Here it [...] -Monitoring function Analogue output module (only for PCD1 and PCD2.M4x60) Analogue output module (only for PCD1 and PCD2.M4x60)
The Advanced Menu is an HTML template which represents a start page with a freely configurable menu, in which all possible types of views as well as PX pages, HTML pages can be integrated by the Saia PCD Supervisor. In addition, alarm lists can be displayed according to priorities and weather information can be displayed as well. Versions: Saia PCD Supervisor 4.10 and higher. In case that the advanced Menu was not used on the Saia PCD Supervisor, then use the file: Advanced Menu v2.4.0.zip If the advanced Menu 2.0 or newer is already used on the Saia PCD Supervisor, then use the
installations. Open communication standards enable the integration of external systems. The easy handling of Saia PCD devices ensures efficient system management, as well as a high operating comfort through the customizable user interface, dedicated dashboards and a remote Function. Saia PCD Supervisor is based on the Niagara 4.13u2 platform from Tridium. This software core has been used successfully worldwide for many years. Compared to the standard version of Tridium, our Saia PCD Supervisor includes, among other advanced BACnet Utilities, an Ether-S-Bus driver, the PG5 Icon Gallery and a PG5 Data Import