Use caution when downloading FW to a PCD3.Mxxxx controller because it is possible downloading a wrong FW (e.g. the one for the PCD2.M480). Once the wrong FW is downloaded follow this procedure for downloading the correct FW:
Old V1.2 ".im5" files are not compatible with V1.3 and later if they were uploaded from a PCD containing Flash or EPROM memory, because the code/text in Flash or EPROM was not uploaded if the PCD contained Flash or EPROM memory.
MC5 mode on F2xxx module All PCD’s: RS485 driver keep holding bus after a while All PCD’s: Http request ‘is modified’ is not handled correctly on the PCD Web-Server which lead to the effect that [...] (CVE-2017-9628) All PCD's: The Modbus CSF CloseSRPort does not free the port then a open/SASI call give an error and the port does not work. PCD1.M2xx0 PCD1.M22x0 PCD2.M4x60: PCD can crash while power down [...] SRPort does not free the port then a open/SASI call give an error and the port does not work. PCD1.M2xx0 PCD1.M22x0 PCD2.M4x60: PCD can crash while power down when XOB 0 is programmed. PCD1.M2xx0 PCD
MC5 mode on F2xxx module All PCD’s: RS485 driver keep holding bus after a while All PCD’s: Http request ‘is modified’ is not handled correctly on the PCD Web-Server which lead to the effect that [...] (CVE-2017-9628) All PCD's: The Modbus CSF CloseSRPort does not free the port then a open/SASI call give an error and the port does not work. PCD1.M2xx0 PCD1.M22x0 PCD2.M4x60: PCD can crash while power down [...] PG5 2.1 and 2.2 with E-Line S-Bus communication library < 1.2.110, why the S-Bus communication on the master PCD stops either after a certain time? (FAQ #102009)
PCD6.E100, PCD6.E610, PCD6.E611 or PCD6.A350 (FAQ #100264) These 4 digital I/O cards have all an address [...] . Nevertheless it is possible measuring the range 0..20 mA with the analogue input modules for PCD systems. Why do the SBC input modules have a range of 0..20 mA? One advantage of measuring the [...] the used power supply does not have the +/-15V the analogic carts can not work. With the PCD4/6.N200 supply it is not possible to use analogic cards. You will need the PCD4/6.N210 supply
PCD6.E100, PCD6.E610, PCD6.E611 or PCD6.A350 (FAQ #100264) These 4 digital I/O cards have all an address [...] . Nevertheless it is possible measuring the range 0..20 mA with the analogue input modules for PCD systems. Why do the SBC input modules have a range of 0..20 mA? One advantage of measuring the [...] the used power supply does not have the +/-15V the analogic carts can not work. With the PCD4/6.N200 supply it is not possible to use analogic cards. You will need the PCD4/6.N210 supply
Product Category Programmable controller PCD2: CPUs, flat design Exxx: Digital inputs E5xx General FAQ PCD2.A3xx Digital output modules (2 A
Product Index PCD2 Exxx: Digital inputs E5xx General FAQ PCD2.A3xx Digital output modules (2 A
Product Category Programmable controller PCD2: CPUs, flat design Exxx: Digital inputs E6xx General FAQ PCD2.A3xx Digital output modules (2 A
version 005 can be found on the PCD4.M1x0 pages. PCD4.M340 (obsolete): CPU0 has got the same firmware as a PCD4.M1x0, the latest version 005 can be found on the PCD4.M1x0 pages. CPU1 with LAN2 has the [...] (or in case a PC is used, by interpreting the tracewin files). This phenomenon can be observed on PCD1.M1x5, PCD2.M150, PCD2/4.M170 and PCS1 systems (with firmware which are supporting the "Secure S [...] appears if the used firmware on the CPU does not support the "active and non ACK" filter for the S-Web alarming functionality (e.g. a PCD2.M150 with firmware 0D3). Symptom Instead of the