Saia PCD® E-Line programmable modules Programmable E-Line input/output module for light and sunblind control supply 24 VAC/VDC 4 digital inputs 24 VAC/VDC 2 relay changeover 230 VAC / 30 VDC, 8 A, max. inrush current 15 A, incl. galvanically isolated current measurement 2 analogue outputs 12 bits, 0…10 V (3 mA max.) 2 interfaces: RS-485 (S-Bus), uUSB for PG5
Saia PCD® E-Line programmable modules Programmable E-Line DALI module for up to 64 DALI ballasts with integrated DALI-Bus power supply supply 24 VAC/VDC 4 digital inputs 24 VAC/VDC 3 interfaces: RS-485 (S-Bus), auxiliary RS-485, uUSB for PG5
PQA - Saia PCD® Power Quality Analyser Power Quality Analyser (PQA) with RS-485 interface LCD 128 x 64 monochrome 1.9" LED for I/O and status supply 110…230 VAC 50/60 Hz measuring inputs 3PH+N up to 270 VAC 1 digital input 24 VDC, high active 1 digital output 5…24 VDC 2 relay normally open 230 VAC, 6 A (resistive load) 1 analogue input for Pt/Ni 1000 sensor 1 interface RS-485 (S-Bus/Modbus) with galvanic isolation
Programmable room controller, 2 interfaces RS-485 for S-Bus or Modbus, Sylk Bus 230 VAC power supply, large housing, RTC, 6 analogue outputs, 4 triac outputs, 4 relays, 1 LED output, 10 universal inputs
Programmable room controller, 2 interfaces RS-485 for S-Bus or Modbus, Sylk Bus 24 VAC power supply, large housing, RTC, 6 analogue outputs, 4 triac outputs, 4 relays, 1 LED output, 10 universal inputs
Programmable room controller, 2 interfaces RS-485 for S-Bus or Modbus, Sylk Bus 230 VAC power supply, large housing, RTC, 2 analogue outputs, 4 triac outputs, 4 relays, 1 LED output, 6 universal inputs
Programmable room controller, 2 interfaces RS-485 for S-Bus or Modbus, Sylk Bus 24 VAC power supply, small housing, RTC, 4 analogue outputs, 2 triac outputs, 4 relays, 4 universal inputs
PG5 Programmable room controller, 2 interfaces RS-485 for S-Bus or Modbus, Sylk Bus 230 VAC power supply, small housing, RTC, 4 analogue outputs, 2 triac outputs, 4 relays, 4 universal inputs
Standby Controller CPU base units for 4 plug-in I/O modules - Saia PCD3.M6 series PCD3 Standby processor unit with 2 Ethernet TCP/IP and Co-processor for Standby operation, web and FTP server, file system, CPU with 2 MByte user program, 1 MByte SRam extension memory, 128 MByte user Flash memory with file system, clock (RTC), data protection 1-3 years, USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-485 for Profi-S-Net/MPI/S-Bus
CPU base units for 4 plug-in I/O modules - Saia PCD3.M5 series PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 2 MByte user program, 128 MByte user Flash memory with file system, clock (RTC), USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-232, RS-422/485, RS-485 for Profi-S-Net/S-Bus, data protection 1-3 years